Počet záznamů: 1
In-situ compression test of artificial bone foams in controlled environment using X-Ray micro-computed tomography
- 1.
SYSNO ASEP 0505071 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název In-situ compression test of artificial bone foams in controlled environment using X-Ray micro-computed tomography Tvůrce(i) Glinz, J. (AT)
Kytýř, Daniel (UTAM-F) SAI, RID, ORCID
Fíla, Tomáš (UTAM-F) RID, SAI, ORCID
Šleichrt, Jan (UTAM-F) RID, ORCID, SAI
Schrempf, A. (AT)
Fürst, D. (AT)
Kastner, J. (AT)
Senck, S. (AT)Celkový počet autorů 8 Zdroj.dok. Acta Polytechnica CTU Proceedings, 25. - Praha : Czech Technical University in Prague, 2019 / Kytýř D. ; Zlámal P. ; Doktor T. - ISBN 978-80-01-06670-6 Rozsah stran s. 48-51 Poč.str. 4 s. Forma vydání Online - E Akce Youth Symposium on Experimental Solid Mechanics /17./ Datum konání 06.06.2019 - 08.06.2019 Místo konání Telč Země CZ - Česká republika Typ akce EUR Jazyk dok. eng - angličtina Země vyd. CZ - Česká republika Klíč. slova x-ray micro-computed tomography ; artificial bone foams ; in-situ testing Vědní obor RIV JJ - Ostatní materiály Obor OECD Materials engineering CEP EF16_019/0000766 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Institucionální podpora UTAM-F - RVO:68378297 EID SCOPUS 85078298752 DOI 10.14311/APP.2019.25.0048 Anotace In this study, we investigated specimens of artificial bone foams, developed by the research group for surgical simulators at the UAS Linz, which are used to mimic the haptic feedback of physiologic and pathologic bone for more realistic surgery training. Specimens with two kinds of mineral filler material as well as different amounts of foaming agent were tested in an environmental in-situ loading stage developed by the ITAM CAS and scanned via X-ray micro-computed tomography. In this in-situ stage, specimens can be immersed in liquid and tested under temperature-controlled conditions. Consequently, a total amount of 12 specimens was subjected to compression loading, half of them immersed in water at 36.5 °C and half in dry condition. Results showed that there is no significant influence of liquid immersion to the compression outcome. However, foams with less amount of foaming agent appeared to have smaller pores resulting in higher compression strength. Pracoviště Ústav teoretické a aplikované mechaniky Kontakt Kulawiecová Kateřina, kulawiecova@itam.cas.cz, Tel.: 225 443 285 Rok sběru 2020 Elektronická adresa https://ojs.cvut.cz/ojs/index.php/APP/article/view/6024
Počet záznamů: 1