Počet záznamů: 1  

Silver Ion High-Performance Liquid Chromatography—Atmospheric Pressure Chemical Ionization Mass Spectrometry: A Tool for Analyzing Cuticular Hydrocarbons

  1. 1.
    SYSNO ASEP0572297
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSilver Ion High-Performance Liquid Chromatography—Atmospheric Pressure Chemical Ionization Mass Spectrometry: A Tool for Analyzing Cuticular Hydrocarbons
    Tvůrce(i) Vrkoslav, Vladimír (UOCHB-X) RID, ORCID
    Horká, Petra (UOCHB-X)
    Jindřich, J. (CZ)
    Buděšínský, Miloš (UOCHB-X) RID, ORCID
    Cvačka, Josef (UOCHB-X) RID, ORCID
    Číslo článku3794
    Zdroj.dok.Molecules. - : MDPI
    Roč. 28, č. 9 (2023)
    Poč.str.17 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovadouble bonds ; hydrocarbons ; mass spectrometry ; Neobellieria bullata ; Periplaneta americana ; semiochemicals
    Obor OECDAnalytical chemistry
    CEPGAP206/12/1093 GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaUOCHB-X - RVO:61388963
    UT WOS000987553200001
    EID SCOPUS85159286144
    DOI10.3390/molecules28093794
    AnotaceAliphatic hydrocarbons (HCs) are usually analyzed by gas chromatography (GC) or matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. However, analyzing long-chain HCs by GC is difficult because of their low volatility and the risk of decomposition at high temperatures. MALDI cannot distinguish between isomeric HCs. An alternative approach based on silver ion high-performance liquid chromatography (Ag-HPLC) is shown here. The separation of HC standards and cuticular HCs was accomplished using two ChromSpher Lipids columns connected in series. A gradient elution of the analytes was optimized using mobile phases prepared from hexane (or isooctane) and acetonitrile, 2-propanol, or toluene. HCs were detected by atmospheric pressure chemical ionization mass spectrometry (APCI-MS). Good separation of the analytes according to the number of double bonds, cis/trans geometry, and position of double bonds was achieved. The retention times increased with the number of double bonds, and trans isomers eluted ahead of cis isomers. The mobile phase significantly affected the mass spectra of HCs. Depending on the mobile phase composition, deprotonated molecules, molecular ions, protonated molecules, and various solvent-related adducts of HCs were observed. The optimized Ag-HPLC/APCI-MS was applied for characterizing cuticular HCs from a flesh fly, Neobellieria bullata, and cockroach, Periplaneta americana. The method made it possible to detect a significantly higher number of HCs than previously reported for GC or MALDI-MS. Unsaturated HCs were frequently detected as isomers differing by double-bond position(s). Minor HCs with trans double bonds were found beside the prevailing cis isomers. Ag-HPLC/APCI-MS has great potential to become a new tool in chemical ecology for studying cuticular HCs.
    PracovištěÚstav organické chemie a biochemie
    Kontaktasep@uochb.cas.cz ; Kateřina Šperková, Tel.: 232 002 584 ; Jana Procházková, Tel.: 220 183 418
    Rok sběru2024
    Elektronická adresahttps://doi.org/10.3390/molecules28093794
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.