SYSNO ASEP 0562894 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Design and Characterisation of an Optical Fibre Dosimeter Based on Silica Optical Fibre and Scintillation Crystal Tvůrce(i) Jelínek, Michal (UPT-D) RID, ORCID, SAI
Číp, Ondřej (UPT-D) RID, SAI, ORCID
Lazar, Josef (UPT-D) RID, ORCID, SAI
Mikel, Břetislav (UPT-D) RID, SAICelkový počet autorů 4 Číslo článku 7312 Zdroj.dok. Sensors. - : MDPI
Roč. 22, č. 19 (2022)Poč.str. 14 s. Forma vydání Online - E Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova gamma radiation measurement ; silica optical fibres ; dosimetry ; fibre sensors ; ionising radiation detection Vědní obor RIV BH - Optika, masery a lasery Obor OECD Optics (including laser optics and quantum optics) CEP EF16_026/0008460 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UPT-D - RVO:68081731 UT WOS 000867073100001 EID SCOPUS 85139920175 DOI 10.3390/s22197312 Anotace In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment's protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics' lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2023 Elektronická adresa https://www.mdpi.com/1424-8220/22/19/7312
Počet záznamů: 1