    NázevHigh-Resolution Strain/Stress Measurements by Three-Axis Neutron Diffractometer
    Tvůrce(i) Mikula, Pavol (UJF-V) RID, ORCID, SAI
    Ryukhtin, Vasil (UJF-V) RID, ORCID, SAI
    Šaroun, Jan (UJF-V) RID, ORCID, SAI
    Strunz, Pavel (UJF-V) RID, ORCID, SAI
    Celkový počet autorů4
    Číslo článku5449
    Zdroj.dok.Materials. - : MDPI
    Roč. 13, č. 23 (2020)
    Poč.str.7 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaresidual stresses ; neutron diffraction ; three axis setting ; high resolution ; bent crystal monochromator ; bent crystal analyzer
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDNuclear related engineering
    CEPLM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF16_013/0001794 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Výzkumná infrastrukturaReactors LVR-15 and LR-0 II - 90120 - Centrum výzkumu Řež s.r.o.
    Způsob publikováníOpen access
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000597561100001
    EID SCOPUS85097011271
    DOI10.3390/ma13235449
    AnotaceResolution properties of the unconventional high-resolution neutron diffraction three-axis setup for strain/stress measurements of large bulk polycrystalline samples are presented. Contrary to the conventional two-axis setups, in this case, the strain measurement on a sample situated on the second axis is carried out by rocking the bent perfect crystal (BPC) analyzer situated on the third axis of the diffractometer. Thus, the so-called rocking curve provides the sample diffraction profile. The neutron signal coming from the analyzer is registered by a point detector. This new setup provides a considerably higher resolution (at least by a factor of 5), which however, requires a much longer measurement time. The high-resolution neutron diffraction setting can be effectively used, namely, for bulk gauge volumes up to several cubic centimeters, and for plastic deformation studies on the basis of the analysis of diffraction line profiles, thus providing average values of microstructure characteristics over the irradiated gauge volume.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2021
    Elektronická adresahttps://doi.org/10.3390/ma13235449
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.