Počet záznamů: 1
High-Resolution Strain/Stress Measurements by Three-Axis Neutron Diffractometer
- 1.
SYSNO ASEP 0538369 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název High-Resolution Strain/Stress Measurements by Three-Axis Neutron Diffractometer Tvůrce(i) Mikula, Pavol (UJF-V) RID, ORCID, SAI
Ryukhtin, Vasil (UJF-V) RID, ORCID, SAI
Šaroun, Jan (UJF-V) RID, ORCID, SAI
Strunz, Pavel (UJF-V) RID, ORCID, SAICelkový počet autorů 4 Číslo článku 5449 Zdroj.dok. Materials. - : MDPI
Roč. 13, č. 23 (2020)Poč.str. 7 s. Forma vydání Online - E Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova residual stresses ; neutron diffraction ; three axis setting ; high resolution ; bent crystal monochromator ; bent crystal analyzer Vědní obor RIV BM - Fyzika pevných látek a magnetismus Obor OECD Nuclear related engineering CEP LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy EF16_013/0001794 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Výzkumná infrastruktura Reactors LVR-15 and LR-0 II - 90120 - Centrum výzkumu Řež s.r.o. Způsob publikování Open access Institucionální podpora UJF-V - RVO:61389005 UT WOS 000597561100001 EID SCOPUS 85097011271 DOI 10.3390/ma13235449 Anotace Resolution properties of the unconventional high-resolution neutron diffraction three-axis setup for strain/stress measurements of large bulk polycrystalline samples are presented. Contrary to the conventional two-axis setups, in this case, the strain measurement on a sample situated on the second axis is carried out by rocking the bent perfect crystal (BPC) analyzer situated on the third axis of the diffractometer. Thus, the so-called rocking curve provides the sample diffraction profile. The neutron signal coming from the analyzer is registered by a point detector. This new setup provides a considerably higher resolution (at least by a factor of 5), which however, requires a much longer measurement time. The high-resolution neutron diffraction setting can be effectively used, namely, for bulk gauge volumes up to several cubic centimeters, and for plastic deformation studies on the basis of the analysis of diffraction line profiles, thus providing average values of microstructure characteristics over the irradiated gauge volume. Pracoviště Ústav jaderné fyziky Kontakt Markéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228 Rok sběru 2021 Elektronická adresa https://doi.org/10.3390/ma13235449
Počet záznamů: 1