Implementation of the orthodoxy test as a validity check on experimental field emission data

  1. 1.
    SYSNO ASEP0524873
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevImplementation of the orthodoxy test as a validity check on experimental field emission data
    Tvůrce(i) Allaham, M. M. (JO)
    Forbes, R. G. (GB)
    Knápek, Alexandr (UPT-D) RID, ORCID, SAI
    Mousa, M. S. (JO)
    Celkový počet autorů4
    Zdroj.dok.Journal of Electrical Engineering - Elektrotechnický časopis. - : Slovenská technická univerzita v Bratislave - ISSN 1335-3632
    Roč. 71, č. 1 (2020), s. 37-42
    Poč.str.6 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.SK - Slovensko
    Klíč. slovafield electron emission ; field emission orthodoxy test ; Fowler-Nordheim plots ; Millikan-Lauritsen plots ; Murphy-Good plots ; field enhancement factor ; emitter characterization parameters
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Obor OECDParticles and field physics
    CEPFV10618 GA MPO - Ministerstvo průmyslu a obchodu
    Způsob publikováníOpen access
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000521829400005
    EID SCOPUS85083636928
    DOI10.2478/jee-2020-0005
    AnotaceIn field electron emission (FE) studies, it is important to check and analyse the quality and validity of experimental current-voltage data, which is usually plotted in one of a small number of standard forms. These include the so-called Fowler-Nordheim (FN), Millikan-Lauritsen (ML) and Murphy-Good (MG) plots. The Field emission orthodoxy test is a simple quantitative test that aims to check for the reasonableness of the values of the parameter “scaled field” that can be extracted from these plots. This is done in order to establish whether characterization parameters extracted from the plot will be reliable or, alternatively, likely to be spurious. This paper summarises the theory behind the orthodoxy test, for each of the plot forms, and confirms that it is easy to apply it to the newly developed MG plot. A simple, new, accessible web application has been developed that extracts scaled-field values from any of these three plot forms, and tests for lack of field emission orthodoxy.