Počet záznamů: 1  

Methods for reduction of time averaged power fluxes in presence of RMP field on ITER.

  1. 1.
    SYSNO ASEP0484390
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVO - Ostatní
    NázevMethods for reduction of time averaged power fluxes in presence of RMP field on ITER.
    Tvůrce(i) Kripner, Lukáš (UFP-V) ORCID
    Urban, Jakub (UFP-V) RID
    Loarte, A. (FR)
    Cahyna, Pavel (UFP-V) RID
    Evans, T. (US)
    Schmitz, O. (DE)
    Pánek, Radomír (UFP-V) RID
    Číslo článkuP3
    Zdroj.dok.643. WE-Heraeus-Seminar: Impact of 3D Magnetic Fields on Hot Plasmas, 643. - Jülich : Forschungszentrum Jülich GmbH, 2017 / Liang Y. ; Sunn Pedersen T. ; Schmitz O. ; Günter S. - ISBN N
    Poč.str.2 s.
    Forma vydáníOnline - E
    AkceWE-Heraeus-Seminar: Impact of 3D magnetic fields on hot plasmas/643./
    Datum konání22.05.2017 - 24.05.2017
    Místo konáníBad Honnef
    ZeměDE - Německo
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovaRMP ; ITER ; Tangle Distance
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPGA16-24724S GA ČR - Grantová agentura ČR
    Institucionální podporaUFP-V - RVO:61389021
    AnotaceThe presence of Edge Localized Modes (ELMs) in large tokamak devices like ITER can lead to exposure of plasma facing components (PFCs) to extremely high power fluxes and consequential melting of PFCs. A very promising method for ELM mitigation and/or suppression is the application of non-axisymmetric magnetic fields, which cause Resonant Magnetic Perturbations (RMPs). However, the application of RMPs can lead to splitting of the strike points into multiple lobes and thus to a non-uniform distribution of the power loads on the divertor. While the ITER plasma in the proximity of a strike-point should be detached, the plasma far from the strike-point remains attached and the increase of the localized power loads in that area can damage the divertor. In this poster, we will present methods that are expected to decrease the time-averaged value of the power load on the divertor. The methods are based on temporal variations of the currents in RMP coils during the discharge. Such a study requires calculations of broad range of target power flux distribution, which is a very demanding process for classical kinetic codes. As a prerequisite for these kinetic simulations we are using the Tangle Distance method [1], which is, due to its analytical nature, capable of efficiently computing a wide range of scenarios. We propose optimized RMP coil currents waveforms with lower ITER LM coils loads than the previously suggested rigid current rotation. [1] Cahyna, P., Peterka, M. et al. Nucl. Fusion (2014), 54(6), 064002.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.