Počet záznamů: 1  

Heat flux distribution and gyro-radius smoothing effect on misaligned CFC tile in the Tore Supra tokamak

  1. 1.
    SYSNO ASEP0433548
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevHeat flux distribution and gyro-radius smoothing effect on misaligned CFC tile in the Tore Supra tokamak
    Tvůrce(i) Corre, Y. (FR)
    Dejarnac, Renaud (UFP-V) RID, ORCID
    Gardarein, J.-L. (FR)
    Gaspar, J. (FR)
    Escourbiac, F. (FR)
    Gauthier, E. (FR)
    Gunn, J. (FR)
    Komm, Michael (UFP-V) RID, ORCID
    Lipa, M. (FR)
    Loarer, T. (FR)
    Missirlian, M. (FR)
    Rigollet, F. (FR)
    Zdroj.dok.21st International Conference on Plasma Surface Interactions 2014. - Toki City : National Institute for Fusion Science, 2014
    P3-086-P3-086
    Poč.str.1 s.
    Forma vydáníTištěná - P
    AkceInternational Conference on Plasma Surface Interactions 2014/21./
    Datum konání26.05.2014-30.05.2014
    Místo konáníKanazawa
    ZeměJP - Japonsko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.JP - Japonsko
    Klíč. slovaHeat loads ; IR thermography ; misalignment ; limiter
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Institucionální podporaUFP-V - RVO:61389021
    AnotaceUnderstanding heat flux deposition processes is essential for the design of the plasma facing component allowing reliable high power steady state plasma operations. Misalignments up to d = 0.2 mm between two adjacent CFC tiles have been reported on the Toroidal Pump Limiter of Tore Supra. Heat flux impinging the top and leading edge of the protruding tile are characterized with both IR thermographic system and numerical modelling using 2D particle-in-cell simulations that accounts for the Larmor radius smoothing effect of energetic ions. Numerical heat loads are coupled with a 2D thermal model of the tile and with a specific sensor correction to simulate spatial-resolution related effects (necessary here since the tile misalignment is smaller than the spatial resolution of the IR system). In the experiment depicted here, with a misalignment smaller than an ion gyro-radius, the Larmor smoothing effect is maximum and overheating of the leading edge is reduced by a factor of two.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.