Počet záznamů: 1  

NOVEL TECHNIQUE FOR DIRECT MEASUREMENT OF THE PLASMA DIFFUSION COEFFICIENT IN MAGNETISED PLASMA

  1. 1.
    SYSNO ASEP0087731
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevNOVEL TECHNIQUE FOR DIRECT MEASUREMENT OF THE PLASMA DIFFUSION COEFFICIENT IN MAGNETISED PLASMA
    Překlad názvuNová metoda pro přímě měření difúzního koeficientu v magnetizovaném plazmatu
    Tvůrce(i) Brotánková, Jana (UFP-V)
    Martines, E. (IT)
    Adámek, Jiří (UFP-V) RID, ORCID
    Stöckel, Jan (UFP-V) RID
    Popa, G. (RO)
    Costin, C. (RO)
    Schrittwieser, R. (AT)
    Ionita, C. (AT)
    Van Oost, G. (BE)
    Zdroj.dok.Book of Abstracts. - Praha, 2007
    S. 40
    Poč.str.2kB
    Forma vydání- - -
    AkceInternational Workshop on Electric Probes in Magnetized Plasmas/7th./
    Datum konání22.7.2007-25.7.2007
    Místo konáníPraha
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaProbes ; ball-pen probe ; katsumata ; edge ; tokamak ; probe diagnostics ; diffusion coefficient
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPKJB100430601 GA AV ČR - Akademie věd
    CEZAV0Z20430508 - UFP-V (2005-2011)
    AnotaceThe diffusion coefficient in the edge plasma of fusion devices is measured by a new technique. The method is based on studying the decay of the plasma fluctuation spectrum inside the so-called “Ball-pen probe” [1]: a small ceramic tube having its mouth flush with a magnetic surface and a movable electrode inside the tube. In the experiment performed in the edge region of the CASTOR tokamak, the probe was used to measure either the floating potential or the ion saturation current. When the electrode protrudes from the tube, the measured signal shows the floating potential fluctuations of the plasma or the ion saturation current outside the tube. Retracting the electrode into the tube, the power spectrum of the signal displays an exponential decay that is different for different frequencies. Assuming a mainly diffusive behaviour of the plasma inside the tube, the spectrum decay length can be used to derive the value of the diffusion coefficient.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2008