Počet záznamů: 1  

One-dimensional scintillator film with benign grain boundaries for high-resolution and fast x-ray imaging

  1. 1.
    SYSNO ASEP0574221
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevOne-dimensional scintillator film with benign grain boundaries for high-resolution and fast x-ray imaging
    Tvůrce(i) Wu, H. (CN)
    Wang, Q. (CN)
    Zhang, A. (CN)
    Niu, G. (CN)
    Nikl, Martin (FZU-D) RID, ORCID, SAI
    Ming, C. (CN)
    Zhu, J. (CN)
    Zhou, Z. (CN)
    Sun, Y.Y. (CN)
    Nan, G. (CN)
    Ren, G. (CN)
    Wu, Y. (CN)
    Tang, J. (CN)
    Celkový počet autorů13
    Číslo článkueadh1789
    Zdroj.dok.Science Advances. - : American Association for the Advancement of Science - ISSN 2375-2548
    Roč. 9, č. 30 (2023)
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovascintillators ; scintillation yield ; x-ray detectors
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDCondensed matter physics (including formerly solid state physics, supercond.)
    CEPEF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS001039293600007
    EID SCOPUS85165990327
    DOI10.1126/sciadv.adh1789
    AnotaceScintillators are indispensable for a number of technologies, including x-ray detectors used in medical imaging and nondestructive inspection, phosphor screens in night-vision systems, electron detectors in electron microscopes, and electromagnetic calorimeter in high-energy physics experiments. Polycrystalline scintillator films are used for most of these applications, especially in x-ray flat panel detector (FPD). Research in this field is largely driven by the aim of high spatial resolution and low afterglow, for tiny-spot identification and high-speed imaging. In terms of spatial resolution, in addition to high scintillation yield, scintillators with optical wave-guiding effect have been designed. The columnar structured scintillator films enjoy low scattering and inter-pixel cross-talk and have demonstrated their intrinsic advantages in high-resolution and high-pixel fill factor for x-ray FPD.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2024
    Elektronická adresahttps://hdl.handle.net/11104/0344566
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.