Počet záznamů: 1  

First analysis of the misaligned leading edges of ITER-like plasma facing units using a very high resolution infrared camera in WEST

  1. 1.
    SYSNO ASEP0541110
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFirst analysis of the misaligned leading edges of ITER-like plasma facing units using a very high resolution infrared camera in WEST
    Tvůrce(i) Grosjean, A. (FR)
    Corre, Y. (FR)
    Dejarnac, Renaud (UFP-V) RID, ORCID
    Gaspar, J. (FR)
    Gunn, J. P. (FR)
    Carpentier-Chouchana, S. (FR)
    Courtois, X. (FR)
    Delmas, E. (FR)
    De Temmerman, G. (FR)
    Diez, M. (FR)
    Dubus, G. (FR)
    Durocher, A. (FR)
    Escourbiac, F. (FR)
    Firdaouss, M. (FR)
    Gerardin, Jonathan (UFP-V) ORCID
    Houry, M. (FR)
    Pitts, R.A. (FR)
    Pocheau, C. (FR)
    Tsitrone, E. (FR)
    Celkový počet autorů19
    Číslo článku106020
    Zdroj.dok.Nuclear Fusion. - : Institute of Physics Publishing - ISSN 0029-5515
    Roč. 60, č. 10 (2020)
    Poč.str.12 s.
    Jazyk dok.eng - angličtina
    Země vyd.AT - Rakousko
    Klíč. slovaheat load ; IR thermography ; ITER-like monoblocks ; leading edge ; plasma facing unit ; very high resolution ; west
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000571855100001
    EID SCOPUS85092048123
    DOI10.1088/1741-4326/ab9fa6
    AnotaceTwelve ITER-like plasma-facing units made of tungsten were exposed in the WEST tokamak divertor, with three plasma-facing units (PFUs) significantly overexposed to plasma heat flux: one sharp-edged PFU (vertical misalignment h = 0.8 mm) and two chamfered PFUs (h =0.6 mm and 0.3 mm, respectively). This paper describes the first temperature analysis obtained with a very high spatial resolution infrared camera (pixel size ∼ 0.1 mm) on the misaligned PFU edges and shows the consistency obtained on the parallel heat flux derived from these measurements. The analysis is focused on the hottest areas of the PFU misaligned leading edges, since the temperature detection threshold of the VHR camera is high (Tthreshold,BB ≈ 370 °C). The heat flux parallel to the magnetic field lines is assessed by matching the toroidal temperature profile in the vicinity of the leading edge with 3D finite element modelling. The tungsten emissivity assumed in this study is 0.6, which is consistent with laboratory measurements for damaged PFUs. For the three PFUs studied (with different vertical misalignments, incident angles, geometries), the derived parallel heat flux is similar, and consistent with independent measurements by a Fiber Bragg grating embedded in a graphite PFU at another toroidal location, giving confidence in future experiments using the same settings.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2021
    Elektronická adresahttps://iopscience.iop.org/article/10.1088/1741-4326/ab9fa6