    NázevMinimum Information for Reporting on the Comet Assay (MIRCA): recommendations for describing comet assay procedures and results
    Tvůrce(i) Moller, P. (DK)
    Azqueta, A. (ES)
    Boutet-Robinet, E. (FR)
    Koppen, G. (BE)
    Bonassi, S. (IT)
    Milić, M. (HR)
    Gajski, G. (IT)
    Costa, S. (PT)
    Teixeira, J. P. (PT)
    Costa Pereira, C. (PT)
    Dusinska, M. (NO)
    Godschalk, R. (NL)
    Brunborg, G. (NO)
    Gützkow, K.B. (NO)
    Giovannelli, L. (IT)
    Cooke, M.S. (US)
    Richling, E. (DE)
    Laffon, B. (ES)
    Valdiglesias, V. (ES)
    Basaran, N. (TR)
    Del Bo', C. (IT)
    Zegura, B. (SK)
    Novák, M. (SK)
    Stopper, H. (DE)
    Vodička, Pavel (UEM-P) RID
    Vodenková, Soňa (UEM-P) ORCID, RID
    de Andrade, V.M. (BR)
    Sramkova, M. (SK)
    Gábelová, A. (SK)
    Collins, A. (NO)
    Langie, S.A.S. (NL)
    Zdroj.dok.Nature Protocols. - : Nature Publishing Group - ISSN 1754-2189
    Roč. 15, č. 12 (2020), s. 3817-3826
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovainter-laboratory variation ; DNA-damage ; animal-models
    Vědní obor RIVCE - Biochemie
    Obor OECDBiochemistry and molecular biology
    Způsob publikováníOpen access
    Institucionální podporaUEM-P - RVO:68378041
    UT WOS000583953500001
    EID SCOPUS85093963487
    DOI10.1038/s41596-020-0398-1
    AnotaceThe comet assay is a widely used test for the detection of DNA damage and repair activity. However, there are interlaboratory differences in reported levels of baseline and induced damage in the same experimental systems. These differences may be attributed to protocol differences, although it is difficult to identify the relevant conditions because detailed comet assay procedures are not always published. Here, we present a Consensus Statement for the Minimum Information for Reporting Comet Assay (MIRCA) providing recommendations for describing comet assay conditions and results. These recommendations differentiate between desirable and essential information: essential information refers to the precise details that are necessary to assess the quality of the experimental work, whereas desirable information relates to technical issues that might be encountered when repeating the experiments. Adherence to MIRCA recommendations should ensure that comet assay results can be easily interpreted and independently verified by other researchers.

    Here, members of the hCOMET COST Action program provide a consensus statement on the Minimum Information for Reporting Comet Assays (MIRCA).
    PracovištěÚstav experimentální medicíny
    KontaktLenka Koželská, lenka.kozelska@iem.cas.cz, Tel.: 241 062 218, 296 442 218
    Rok sběru2021
    Elektronická adresahttps://www.nature.com/articles/s41596-020-0398-1
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.