Počet záznamů: 1  

Floating harmonic probe measurements in the low-temperature plasma jet deposition system

  1. 1.
    SYSNO ASEP0489658
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFloating harmonic probe measurements in the low-temperature plasma jet deposition system
    Tvůrce(i) Zanáška, M. (CZ)
    Hubička, Zdeněk (FZU-D) RID, ORCID, SAI
    Čada, Martin (FZU-D) RID, ORCID, SAI
    Kudrna, P. (CZ)
    Tichý, M. (CZ)
    Celkový počet autorů5
    Číslo článku025205
    Zdroj.dok.Journal of Physics D-Applied Physics. - : Institute of Physics Publishing - ISSN 0022-3727
    Roč. 51, č. 2 (2018), s. 1-8
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaplasma diagnostic ; floating harmonic probe ; Langmuir probe ; hollow cathode ; non-conducting film deposition
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPGA15-00863S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000418383500001
    EID SCOPUS85039694504
    DOI10.1088/1361-6463/aa9d3b
    AnotaceThe floating harmonic probe is a relatively new plasma diagnostic method, which was proposed for applications at conditions when insulating films are deposited on the probe and, consequently, the classical Langmuir probe method fails. In the floating harmonic probe method a purely sinusoidal AC voltage is applied to the probe constructed in a standard manner via a capacitor. From the spectral components of the measured AC probe current waveforms, the electron temperature and the positive ion density can be obtained. In this contribution we present the comparison of the electron temperature and density acquired by the floating harmonic probe method with those obtained by the classical Langmuir probe. The experiments are performed in the flowing DC discharge in argon. In addition, the results from the floating harmonic probe method obtained during deposition of an insulating iron oxide thin film are shown. All the data is complemented by the qualitative discussion.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2019
    Elektronická adresahttps://doi.org/10.1088/1361-6463/aa9d3b
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.