Počet záznamů: 1  

Role of silica nanoparticles in monitoring and prolonging release of drug-eluting polyelectrolyte coatings using long-period fiber grating platform

  1. 1.
    SYSNO ASEP0484862
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevRole of silica nanoparticles in monitoring and prolonging release of drug-eluting polyelectrolyte coatings using long-period fiber grating platform
    Tvůrce(i) Tian, F. (US)
    Kaňka, Jiří (URE-Y)
    Yang, F. (US)
    Min, J. (US)
    Hammond, P. T. (US)
    Celkový počet autorů5
    Zdroj.dok.Sensors and Actuators B - Chemical. - : Elsevier
    Roč. 252, November (2017), s. 831-839
    Poč.str.9 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaLong period gratings ; Sensor ; Layer-by-layer assembly
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Obor OECDElectrical and electronic engineering
    CEPGBP205/12/G118 GA ČR - Grantová agentura ČR
    Institucionální podporaURE-Y - RVO:67985882
    UT WOS000408277500098
    EID SCOPUS85020908616
    DOI10.1016/j.snb.2017.06.048
    Anotaceilica nanoparticles (SNPs) were synergistically integrated with long-period grating (LPG) platform and the process of layer-by-layer (LbL) assembly to enable monitoring controlled release of drug-eluting polyelectrolyte coatings. The SNPs afforded a high surface area for increased drug loading as well as enhanced evanescent field overlap. In addition, the SNPs positioned within the LbL coatings acted as diffusion barrier layer, leading to prolonged release profile. SNPs with different sizes were respectively immobilized on the LPG using poly allylamine hydrochloride (PAH). In-situ monitoring of drug-eluting LbL coating [chitosan (CHI)/Poly arylic acid (PAA)/Gentamicin sulfate (GS)PAA](n), was carried out on LPG with a sensitivity of 8.1 nm shift/tetralayer for LPG with 1 layer of SNPs with 50 nm in diameter. LPG without the SNPs for the monitoring of [CHI/PAA/GS/PAA](n) shows a sensitivity of 2.4 nm shift/tetralayer, indicating the significant ability of SNPs in enhancing the LPG sensitivity. Drug release measurement carried out on the LPG platform revealed an increased release time for LbL-SNP drug delivery system compared with that of LbL alone
    PracovištěÚstav fotoniky a elektroniky
    KontaktPetr Vacek, vacek@ufe.cz, Tel.: 266 773 413, 266 773 438, 266 773 488
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.