Počet záznamů: 1  

Fabrication of diamond based quartz crystal microbalance gas sensor

  1. 1.
    SYSNO ASEP0432192
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevFabrication of diamond based quartz crystal microbalance gas sensor
    Tvůrce(i) Varga, Marián (FZU-D) RID, ORCID
    Laposa, A. (CZ)
    Kulha, P. (CZ)
    Davydova, Marina (FZU-D) RID, ORCID
    Kroutil, J. (CZ)
    Husák, M. (CZ)
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Zdroj.dok.Key Engineering Materials : Materials and Applications for Sensors and Transducers III, 605. - Zurich : Trans Tech Publications, 2014 / Hristoforou E. ; Vlachos D.S. - ISSN 1013-9826 - ISBN 9783038350514
    Rozsah strans. 589-592
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceInternational Conference on Materials and Applications for Sensors and Transducers /3./ (IC-MAST 2013)
    Datum konání13.09.2013-17.09.2013
    Místo konáníPraha
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovadiamond thin film ; low temperature deposition ; quartz crystal microbalance ; gas sensor
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    CEPGAP108/11/0794 GA ČR - Grantová agentura ČR
    Institucionální podporaFZU-D - RVO:68378271
    EID SCOPUS84900427545
    DOI10.4028/www.scientific.net/KEM.605.589
    AnotaceSynthetic diamond has remarkable properties comparable with natural diamond and hence is a very promising material for many various applications. Nowadays, deposition of diamond films is normally employed in chemical vapor deposition (CVD) usually at high temperatures, what limit its application to high melting substrates. Gravimetric (mass) sensors belong to the major categories of chemical sensors and the most common type of mass sensor is the bulk acoustic quartz crystal microbalance (QCM). This contribution deals with a NCD growth from the H2/CH4/CO2 gas mixture at low temperature (400 °C) by pulsed linear antenna MWCVD plasma system on 10 MHz circular AT-cut quartz resonators substrate. Gas sensor based on the NCD-coated QCM was developed for detection of ammonia at room temperature. Measurements not only confirmed the functionality of this first published NCD-coated QCM sensor, but in addition its sensitivity was twofold to a virgin QCM sensor with a gold active layer.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.