Počet záznamů: 1  

VLBI receiver chain monitoring

  1. 1.
    SYSNO ASEP0396960
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevVLBI receiver chain monitoring
    Tvůrce(i) Michálek, V. (CZ)
    Kodet, J. (CZ)
    Schreiber, U. (DE)
    Ploetz, Ch. (DE)
    Procházka, I. (CZ)
    Pánek, Petr (URE-Y) RID
    Celkový počet autorů6
    Zdroj.dok.Proceeding 2013 Joint European Frequency and Time Forum and International Frequency Control Symposium, EFTF/IFC 2013. - Praha : IEEE, 2013 - ISBN 9781479903429
    Rozsah strans. 854-856
    Poč.str.3 s.
    Forma vydáníNosič - C
    Akce2013 Joint UFFC, EFTF and PFM Symposium
    Datum konání21.07.2013-25.07.2013
    Místo konáníPrague
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaFrequency standards ; Calibration ; Two-way time transfers
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Institucionální podporaURE-Y - RVO:67985882
    EID SCOPUS84893263213
    DOI10.1109/EFTF-IFC.2013.6702153
    Anotacehe most demanding goal of the Global Geodetic Observing System initiative is the definition of station positions to an accuracy of 1mm and the corresponding velocities to 0.1 mm/year. The main remaining sources of error are caused by systematics, leading to intra- and inter- technique biases. In this work, we have focused on Very Long Base Interferometry (VLBI) and phase calibration generator currently in operation. This unit is injecting calibration tones into the detection chain through an input coupler located near the input of the antenna. The tones propagate further through entire detection chain and are recorded with the observed signal. Then they are extracted in post processing. These tones are generated out of an atomic frequency standard. The supplied frequency is significantly influenced by temperature and mechanical changes since usually a long cable is employed to bring the frequency to the calibration unit. To monitor the electrical length of the cable, calibration with a picosecond precision is essential. We have redesigned a phase calibration unit so that it enables the implementation of the Two Way Time Transfer (TWTT) method on single coaxial cable using two event timers to monitor the electrical length of the critical cable. Such a system has been installed in parallel to the unit currently in operation. The comparison of the TWTT method with previous measurement method is presented
    PracovištěÚstav fotoniky a elektroniky
    KontaktPetr Vacek, vacek@ufe.cz, Tel.: 266 773 413, 266 773 438, 266 773 488
    Rok sběru2014
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.