- On Use of Semiconductor Detector Arrays on COMPASS Tokamak
Počet záznamů: 1  

On Use of Semiconductor Detector Arrays on COMPASS Tokamak

  1. 1.
    SYSNO ASEP0386246
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JOstatní články
    NázevOn Use of Semiconductor Detector Arrays on COMPASS Tokamak
    Tvůrce(i) Weinzettl, Vladimír (UFP-V) RID, ORCID
    Imríšek, Martin (UFP-V) RID
    Havlíček, Josef (UFP-V) RID, ORCID
    Mlynář, Jan (UFP-V) RID
    Naydenkova, Diana (UFP-V) RID, ORCID
    Háček, Pavel (UFP-V) RID, ORCID
    Hron, Martin (UFP-V) RID, ORCID
    Janky, Filip (UFP-V) RID
    Sarychev, D. (RU)
    Berta, M. (HU)
    Bencze, A. (HU)
    Szabolics, T. (HU)
    Zdroj.dok.World Academy of Science, Engineering and Technology - ISSN 2010-376X
    -, č. 71 (2012), s. 844-850
    Poč.str.7 s.
    Forma vydáníweb - web
    AkceICPP 2012 : International Conference on Plasma Physics
    Datum konání14.11.2012-16.11.2012
    Místo konáníVenice
    ZeměIT - Itálie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.AE - Spojené arabské emiráty
    Klíč. slovabolometry ; plasma diagnostics ; soft X-rays ; tokamak
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPGA202/09/1467 GA ČR - Grantová agentura ČR
    GAP205/11/2470 GA ČR - Grantová agentura ČR
    7G10072 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2011021 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z20430508 - UFP-V (2005-2011)
    AnotaceSemiconductor detector arrays are widely used in high-temperature plasma diagnostics. They have a fast response, which allows observation of many processes and instabilities in tokamaks. In this paper, there are reviewed several diagnostics based on semiconductor arrays as cameras, AXUV photodiodes (referred often as fast “bolometers”) and detectors of both soft X-rays and visible light installed on the COMPASS tokamak recently. Fresh results from both spring and summer campaigns in 2012 are introduced. Examples of the utilization of the detectors are shown on the plasma shape determination, fast calculation of the radiation center, two-dimensional plasma radiation tomography in different spectral ranges, observation of impurity inflow, and also on investigation of MHD activity in the COMPASS tokamak discharges.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2013
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.