Počet záznamů: 1  

Implementation of Broadband Electrically Detected Magnetic Resonance in a Sub-THz FraScan Spectrometer

  1. 1.
    SYSNO ASEP0579273
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevImplementation of Broadband Electrically Detected Magnetic Resonance in a Sub-THz FraScan Spectrometer
    Tvůrce(i) Solodovnyk, A. (CZ)
    Savchenko, Dariia (FZU-D) RID, ORCID
    Laguta, O. (CZ)
    Neugebauer, P. (CZ)
    Celkový počet autorů4
    Číslo článku6006708
    Zdroj.dok.IEEE Transactions on Instrumentation and Measurement. - : Institute of Electrical and Electronics Engineers - ISSN 0018-9456
    Roč. 72, June (2023)
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaspin-dependent recombination ; thin-film silicon ; transport ; centers ; 15R SiC ; electrically detected magnetic resonance (EDMR) ; frequency-domain EDMR (FD EDMR) ; magnetic resonance ; SiC ; sub-THz ; THz
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDCondensed matter physics (including formerly solid state physics, supercond.)
    CEPEF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS001022135200006
    EID SCOPUS85162878241
    DOI10.1109/TIM.2023.3284951
    AnotaceElectrically detected magnetic resonance (EDMR) is an effective spectroscopic method used for characterizing semiconductive solid-state materials. High spin sensitivity and the capability to explore spin-dependent transport mechanisms, which are crucial for the development of semiconductor devices, define it from other methods based on magnetic resonance. High frequency and high magnetic field EDMR implementation was motivated by the necessity to obtain access to more precise, high-resolution data to enhance the method’s research potential. We present an EDMR system based on a unique THz FraScan spectrometer, which performs frequency sweeps ranging from 80 GHz to 1.1 THz, and the magnetic field sweeps up to 16 T. The study addresses the instrumentation, detection scheme, and 85–328.84-GHz EDMR results on highly nitrogen-doped 15R SiC monocrystals.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2024
    Elektronická adresahttps://hdl.handle.net/11104/0348125