Počet záznamů: 1  

Measuring venous-arterial differences of valine, isoleucine, leucine, alanine and glutamine in skeletal muscles using counter-current electrophoresis with contactless conductivity detection

  1. 1.
    SYSNO ASEP0519392
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevMeasuring venous-arterial differences of valine, isoleucine, leucine, alanine and glutamine in skeletal muscles using counter-current electrophoresis with contactless conductivity detection
    Tvůrce(i) Tůma, P. (CZ)
    Gojda, J. (CZ)
    Sommerová, B. (CZ)
    Koval, Dušan (UOCHB-X) RID, ORCID
    Číslo článku113772
    Zdroj.dok.Journal of Electroanalytical Chemistry. - : Elsevier - ISSN 1572-6657
    Roč. 857, Jan 15 (2020)
    Poč.str.6 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovabranched chain amino acids ; clinical analysis ; capillary electrophoresis ; coating ; contactless conductivity detection
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    CEPGA17-12648S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUOCHB-X - RVO:61388963
    UT WOS000518494300030
    EID SCOPUS85076996162
    DOI10.1016/j.jelechem.2019.113772
    AnotacePlasmatic levels of valine, isoleucine, leucine, alanine and glutamine were determined by capillary electrophoresis with contactless conductivity detection. A new kind of covalently coated capillary based on polyacrylamide and (3-acrylamidopropyl) trimethylammonium chloride was employed. The amino acids were separated in the counter-current regime, in which the analytes migrate under counter-current electro-osmotic flow with a value of 5.53 · 10−9 m2 V−1 s−1 in the background electrolyte, 3.2 mol/L AcOH +10% v/v MeOH. The baseline separation of all five amino acids from other plasmatic compounds was achieved in <5 min, the limits of detections are 0.13–0.14 μmol/L for the treated sample and 0.50–0.58 μmol/L for the untreated plasma. The method was used to measure venous-arterial differences of amino acids in hyperinsulinemic patients with cachexia.
    PracovištěÚstav organické chemie a biochemie
    Kontaktasep@uochb.cas.cz ; Kateřina Šperková, Tel.: 232 002 584 ; Jana Procházková, Tel.: 220 183 418
    Rok sběru2021
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S1572665719310409?via%3Dihub
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.