Počet záznamů: 1  

Ion microprobe improvements in Tandetron Laboratory NPI CAS: Numerical calculation

  1. 1.
    SYSNO ASEP0509714
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevIon microprobe improvements in Tandetron Laboratory NPI CAS: Numerical calculation
    Tvůrce(i) Romanenko, Oleksandr V. (UJF-V) ORCID, SAI
    Ponomarev, A. G. (UA)
    Macková, Anna (UJF-V) RID, ORCID, SAI
    Havránek, Vladimír (UJF-V) RID, SAI, ORCID
    Ponomarov, A. (CN)
    Celkový počet autorů5
    Zdroj.dok.Nuclear Instruments & Methods in Physics Research Section B. - : Elsevier - ISSN 0168-583X
    Roč. 458, č. 11 (2019), s. 77-81
    Poč.str.5 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovanuclear microprobe ; spaced triplet ; acceptance ; spatial resolution
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    Obor OECDNuclear physics
    CEPEF16_013/0001812 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GBP108/12/G108 GA ČR - Grantová agentura ČR
    LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000486134400012
    EID SCOPUS85070547161
    DOI10.1016/j.nimb.2019.08.007
    AnotaceIon scanning microprobe was implemented in the Tandetron Laboratory, Nuclear Physics Institute of the Czech Academy of Sciences (NPI CAS) in Rez in 2009. Rez microprobe is coupled with a tandetron accelerator, which provides ions from hydrogen to gold, and able to focus heavy ions with the maximum mass energy product at the level 11 MeV amu/q(2). Therefore, microprobe can be used for polymers irradiation by protons and helium as well as for irradiation of various types of glass and other materials with heavy ions. The number of applications for the microprobe in the Tandetron Laboratory is constantly increasing, that leads to the necessity to raise the efficiency of the microprobe operation. Increasing the beam current density allows for a reduction in the time per experiment in relation to recording the number of events. The present work is an attempt to improve the parameters of existing ion scanning microprobe based on a compact Oxford triplet lens system. Since the microprobe is used to investigate both thin and thick targets, the position of the detectors that can restrict the microprobe construction were taken into account in the calculation. The collimated acceptance of the probe-forming system was selected as an objective function as it takes into account both chromatic and all spherical aberrations. Two methods for improving the microprobe parameters were considered. The first one is based on separation of the first lens in the system, whilst the second - on decreasing the working distance. Both ways need changing in the microprobe construction, but the last one requires a major alteration in a target chamber. The benefits of each way were studied. Obtained parameters of the new probe-forming system have shown a two fold increase of the current density of the given probe size for Rez microprobe in comparison with the present system. The benefits of the displacement of the first lens disappear with the decreasing of the working distance.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2020
    Elektronická adresahttps://doi.org/10.1016/j.nimb.2019.08.007