- Dynamic studies of antibody-antigen interactions with an electrolyte-…
Počet záznamů: 1  

Dynamic studies of antibody-antigen interactions with an electrolyte-gated organic transistor

  1. 1.
    SYSNO ASEP0604893
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDynamic studies of antibody-antigen interactions with an electrolyte-gated organic transistor
    Tvůrce(i) Urbina, P.A.M. (IT)
    Paradisi, A. (IT)
    Hasler, R. (AT)
    Sensi, M. (IT)
    Berto, M. (IT)
    Saygin, G.D. (IT)
    Dostálek, Jakub (FZU-D) ORCID, RID
    Pinti, M. (IT)
    Greco, P. (IT)
    Borsari, M. (IT)
    Knoll, W. (AT)
    Bortolotti, C.A. (IT)
    Biscarini, F. (IT)
    Celkový počet autorů13
    Číslo článku101919
    Zdroj.dok.Cell Reports Physical Science. - : Cell Press
    Roč. 5, č. 8 (2024)
    Poč.str.18 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovasurface plasmon resonance ; field-effect transistor ; biosensor ; biomolecular interaction analysis
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPGC22-30456J GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS001301222400001
    EID SCOPUS85191892001
    DOI https://doi.org/10.1016/j.xcrp.2024.101919
    AnotaceAffinity-based biosensors employing surface-bound biomolecules for analyte detection are important tools in clinical diagnostics and drug development. In this context, electrolyte-gated organic transistors (EGOTs) are emerging as ultrasensitive label-free biosensors. In this study, we present an EGOT sensor integrated within a microfluidic system. The sensor utilizes the cytomegalovirus (CMV) phosphoprotein 65 as a biorecognition element to detect the pathological biomarker human anti-cytomegalovirus antibody in solution. The biorecognition element is grafted onto the gate electrode by exploiting the polyhistidine-tag technology. Real-time monitoring of the EGOT response, coupled with a two compartment kinetic model analysis, enables the determination of analyte concentration, binding kinetics, and thermodynamics of the interaction.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2025
    Elektronická adresahttps://hdl.handle.net/11104/0362438
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.