Compact absorbance detector for portable microcolumn liquid chromatography instrument

  1. 1.
    SYSNO ASEP0576348
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevCompact absorbance detector for portable microcolumn liquid chromatography instrument
    Tvůrce(i) Gogaľová, Zuzana (UIACH-O) ORCID
    Šesták, Jozef (UIACH-O) ORCID
    Lunerová, K. (CZ)
    Celkový počet autorů3
    Zdroj.dok.ITP 2023. Abstracts. -, 2023
    S. 139-139
    Poč.str.1 s.
    Forma vydáníOnline - E
    AkceInternational Symposium on Electro- and Liquid-Phase Separation Techniques /29./ ITP 2023
    Datum konání13.09.2023 - 17.09.2023
    Místo konáníSan Felice Circeo
    ZeměIT - Itálie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.IT - Itálie
    Klíč. slovaabsorbance detection ; capillary flow cell ; effective optical path ; portable HPLC ; miniaturization
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    CEPVI04000062 GA MV - Ministerstvo vnitra
    Institucionální podporaUIACH-O - RVO:68081715
    AnotaceThe development of miniaturized liquid chromatography systems (LC) for in situ analysis requires adequate miniaturization at the level of individual system components. An important component of any LC system is the detector, which is responsible for detection of the separated components and generating a signal that can be used for identification and quantification of analyte. In optical detectors, the design of the detection flow cell plays a crucial role in the overall performance of the LC system. Herein we present some preliminary results characterizing compact UV-Vis absorbance detector comprising miniature deuterium lamp, 97 nL capillary flow cell and CCD spectrometer. Detection cell is coupled to the light source and CCD spectrometer by the optical fibres integrated in the flow cell structure. In the cell performance test, acetone-water mixture was measured and the effective optical path of the cell was 5.3 mm. Absorbance baseline noise depended on the selected wavelength (210 – 610 nm) as well as on the integration time (25 – 200 ms) and was in the range of 1.332 – 9.405 mAU. In isocratic chromatography separation of the test mixtures, the performance of the proposed detector was compared with the commercial DAD detector equipped with 80 nL rectangular flow cell. In conclusion, the proposed detector and capillary flow cell design are suitable for portable LC instruments.