SYSNO ASEP 0571763 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Relative entropy is an easy-to-use invasive electroencephalographic biomarker of the epileptogenic zone Tvůrce(i) Trávníček, Vojtěch (UPT-D) ORCID, RID, SAI
Klimeš, Petr (UPT-D) RID, ORCID, SAI
Cimbálník, J. (CZ)
Halámek, Josef (UPT-D) RID, ORCID, SAI
Jurák, Pavel (UPT-D) RID, ORCID, SAI
Brinkmann, B. (US)
Balzekas, I. (US)
Abdallah, C. (CA)
Dubeau, F. (CA)
Frauscher, B. (CA)
Worrell, G. A. (US)
Brázdil, M. (CZ)Celkový počet autorů 12 Zdroj.dok. Epilepsia. - : Wiley - ISSN 0013-9580
Roč. 64, č. 4 (2023), s. 962-972Poč.str. 11 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova drug-resistant epilepsy ; iEEG ; SOZ localization Vědní obor RIV FH - Neurologie, neurochirurgie, neurovědy Obor OECD Neurosciences (including psychophysiology CEP NU22-08-00278 GA MZd - Ministerstvo zdravotnictví GA22-28784S GA ČR - Grantová agentura ČR GA21-25953S GA ČR - Grantová agentura ČR LX22NPO5107 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LTAUSA18056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UPT-D - RVO:68081731 UT WOS 000942976500001 EID SCOPUS 85150234093 DOI 10.1111/epi.17539 Anotace Objective: High-frequency oscillations are considered among the most promising interictal biomarkers of the epileptogenic zone in patients suffering from pharmacoresistant focal epilepsy. However, there is no clear definition of pathological high-frequency oscillations, and the existing detectors vary in methodology, performance, and computational costs. This study proposes relative entropy as an easy-to-use novel interictal biomarker of the epileptic tissue.Methods: We evaluated relative entropy and high-frequency oscillation biomarkers on intracranial electroencephalographic data from 39 patients with seizure-free postoperative outcome (Engel Ia) from three institutions. We tested their capability to localize the epileptogenic zone, defined as resected contacts located in the seizure onset zone. The performance was compared using areas under the receiver operating curves (AUROCs) and precision-recall curves. Then we tested whether a universal threshold can be used to delineate the epileptogenic zone across patients from different institutions.Results: Relative entropy in the ripple band (80-250 Hz) achieved an average AUROC of .85. The normalized high-frequency oscillation rate in the ripple band showed an identical AUROC of .85. In contrast to high-frequency oscillations, relative entropy did not require any patient-level normalization and was easy and fast to calculate due to its clear and straightforward definition. One threshold could be set across different patients and institutions, because relative entropy is independent of signal amplitude and sampling frequency.Significance: Although both relative entropy and high-frequency oscillations have a similar performance, relative entropy has significant advantages such as straightforward definition, computational speed, and universal interpatient threshold, making it an easy-to-use promising biomarker of the epileptogenic zone. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2024 Elektronická adresa https://onlinelibrary.wiley.com/doi/10.1111/epi.17539
Počet záznamů: 1