Počet záznamů: 1  

Advanced Tool for Chiral Separations of Anionic and Zwitterionic (Metalla)carboranes: Supercritical Fluid Chromatography

  1. 1.
    SYSNO ASEP0566035
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevAdvanced Tool for Chiral Separations of Anionic and Zwitterionic (Metalla)carboranes: Supercritical Fluid Chromatography
    Tvůrce(i) Horáček, O. (CZ)
    Nováková, L. (CZ)
    Tüzün, Ece Zeynep (UACH-T) ORCID, RID, SAI
    Grüner, Bohumír (UACH-T) RID, SAI, ORCID
    Švec, F. (CZ)
    Kučera, R. (CZ)
    Celkový počet autorů6
    Zdroj.dok.Analytical Chemistry. - : American Chemical Society - ISSN 0003-2700
    Roč. 94, č. 50 (2022), s. 17551-17558
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaAnions ; Cobalt ; Mixtures ; Reaction products ; Selectivity
    Vědní obor RIVCA - Anorganická chemie
    Obor OECDInorganic and nuclear chemistry
    CEPGA21-14409S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUACH-T - RVO:61388980
    UT WOS000893797700001
    EID SCOPUS85143878207
    DOI10.1021/acs.analchem.2c03895
    AnotaceThe continuous expansion of research in the field of stable carboranes and their wide potential in the drug design require carrying out fundamental studies regarding their chiral separations. Although supercritical fluid chromatography (SFC) is a viable technique for fast enantioseparations, no investigation concerning boron cluster compounds has been done yet. We aimed at the development of a straightforward method enabling chiral separations of racemic mixtures of anionic cluster carboranes and metallacarboranes that represent an analytical challenge. The fast gradient screening testing nine polysaccharide-based columns was used. The key parameters affecting the selectivity were the type of chiral selector, the type of alcohol, and the base in cosolvent. Moreover, the addition of acetonitrile or water to the cosolvent was identified as an effective tool for decreasing the analysis time while preserving the resolution. After the optimization, the chiral separations of 19 out of 20 selected compounds were achieved in less than 10 min. These results demonstrate the clear advantage of SFC over chiral separations using HPLC in terms of both analysis time and structural variety of successfully separated compounds.
    PracovištěÚstav anorganické chemie
    KontaktJana Kroneislová, krone@iic.cas.cz, Tel.: 311 236 931
    Rok sběru2023
    Elektronická adresahttps://doi.org/10.1021/acs.analchem.2c03895