Počet záznamů: 1
Biological autoluminescence as a non-invasive monitoring tool for pulsed electric field effects on yeast cells
- 1.
SYSNO ASEP 0560868 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Biological autoluminescence as a non-invasive monitoring tool for pulsed electric field effects on yeast cells Tvůrce(i) Bereta, M. (SK)
Teplan, M. (SK)
Chafai, Djamel Eddine (FZU-D)
Cifra, Michal (URE-Y) RID, ORCID, SAICelkový počet autorů 4 Číslo článku 9232161 Zdroj.dok. 33rd General Assembly and Scientific Symposium (GASS) of the International-Union-of-Radio-Science (URSI) 2020. - New York : IEEE, 2020 - ISBN 978-9-4639-6800-3 Poč.str. 3 s. Forma vydání Online - E Akce General Assembly and Scientific Symposium (GASS) of the International-Union-of-Radio-Science (URSI) /33./ Datum konání 29.08.2020 - 05.08.2020 Místo konání Řím Země IT - Itálie Typ akce WRD Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova biology ; electric fields ; monitoring ; biomedical measurement ; photonics ; tools ; pulse measure Vědní obor RIV BO - Biofyzika Obor OECD Medical laboratory technology (including laboratory samples analysis Vědní obor RIV – spolupráce Ústav fotoniky a elektroniky - Elektronika a optoelektronika, elektrotechnika CEP GA18-23597S GA ČR - Grantová agentura ČR Institucionální podpora FZU-D - RVO:68378271 ; URE-Y - RVO:67985882 UT WOS 000632276400087 EID SCOPUS 85096869533 DOI 10.23919/URSIGASS49373.2020.9232161 Anotace The application of pulsed electric field (PEF) is nowadays becoming a very promising tool for application in medicine or food industry. However, the mechanisms of PEF interaction with living matter are still not fully elucidated. The aim of the presented work is to show the potential application of biological autoluminescence (BAL) for monitoring of pulsed electric field (PEF) biological effects on yeasts. The yeast cell culture (Saccharomyces cerevisiae) is exposed to the pulsed electric field (pulse duration: 0.1-5 ms, pulse number: 1-10, electric field strength: 3 kV.cm(-1)) and the BAL is monitored during exposure. The results indicate detectable differences in BAL dynamics when PEF is applied. Due to its non-invasive and label-free application, the BAL could be used as a beneficial tool for monitoring of PEF biological effects. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2023 Elektronická adresa https://ieeexplore.ieee.org/document/9232161/authors#authors
Počet záznamů: 1