Počet záznamů: 1
Nanocrystalline diamond electrolyte-gates in field effect transistor for a prolific aptasensing HIV-1 tat on hydrogen-terminated surface
- 1.
SYSNO ASEP 0538344 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Nanocrystalline diamond electrolyte-gates in field effect transistor for a prolific aptasensing HIV-1 tat on hydrogen-terminated surface Tvůrce(i) Ahmad, N.A. (MY)
Rahim, R.A. (MY)
Rezek, Bohuslav (FZU-D) RID, ORCID
Kromka, Alexander (FZU-D) RID, ORCID, SAI
Ismail, N.S. (MY)
Gopinath, S.Ch.B. (MY)
Ižák, Tibor (FZU-D) RID
Procházka, V. (CZ)
Faudzi, F.N.M. (MY)
Abidin, A.S.Z. (MY)
Maidizn, N.N.M. (MY)Celkový počet autorů 11 Zdroj.dok. International Journal of Nanoelectronics and Materials. - : Universiti Malaysia Perlis - ISSN 1985-5761
Roč. 13, č. 2 (2020), s. 295-306Poč.str. 12 s. Jazyk dok. eng - angličtina Země vyd. MY - Malajsie Klíč. slova aptamer ; electrolyte-gated field effect transistor ; HIV-1 Tat ; nanocrystalline diamonds Vědní obor RIV JB - Senzory, čidla, měření a regulace Obor OECD Nano-materials (production and properties) CEP EF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora FZU-D - RVO:68378271 UT WOS 000531045800006 EID SCOPUS 85085315022 Anotace This research investigated on Trans-activator of transcription (Tat) protein, a powerful viral gene activator that plays a pivotal role in the primary stage of the human immunodeficiency virus type 1 (HIV-1) replication. Dose-dependent interactions of HIV-1 Tat on NCD-EGFET-based RNA aptamer sensing surface were monitored and attained the detection down to 10 fM. The linear regression curve with 3σ estimation professed the sensitivity range to be 31.213 mV/log10 [Tat Concentration]M and the limit of detection of 6.18 fM. The selectivity analysis of NCD-EGFET was conducted with different proteins from HIV (Nef and p24) and Bovine Serum Albumin. Furthermore, to practice in the clinical application, HIV-1 Tat was spiked into the human blood serum and it displayed the genuine non-fouling interaction with the aptamer. The attained high-performance signal enhancement with nanocrystalline diamond-biosensing aids to circumvent the issues in the current diagnosis. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2021 Elektronická adresa https://ijneam.unimap.edu.my/images/PDF/IJNEAM%20APR%202020/Vol_13_No_2_2020_7_295-306.pdf
Počet záznamů: 1