Počet záznamů: 1  

Nanocrystalline diamond electrolyte-gates in field effect transistor for a prolific aptasensing HIV-1 tat on hydrogen-terminated surface

  1. 1.
    SYSNO ASEP0538344
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevNanocrystalline diamond electrolyte-gates in field effect transistor for a prolific aptasensing HIV-1 tat on hydrogen-terminated surface
    Tvůrce(i) Ahmad, N.A. (MY)
    Rahim, R.A. (MY)
    Rezek, Bohuslav (FZU-D) RID, ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Ismail, N.S. (MY)
    Gopinath, S.Ch.B. (MY)
    Ižák, Tibor (FZU-D) RID
    Procházka, V. (CZ)
    Faudzi, F.N.M. (MY)
    Abidin, A.S.Z. (MY)
    Maidizn, N.N.M. (MY)
    Celkový počet autorů11
    Zdroj.dok.International Journal of Nanoelectronics and Materials. - : Universiti Malaysia Perlis - ISSN 1985-5761
    Roč. 13, č. 2 (2020), s. 295-306
    Poč.str.12 s.
    Jazyk dok.eng - angličtina
    Země vyd.MY - Malajsie
    Klíč. slovaaptamer ; electrolyte-gated field effect transistor ; HIV-1 Tat ; nanocrystalline diamonds
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    Obor OECDNano-materials (production and properties)
    CEPEF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000531045800006
    EID SCOPUS85085315022
    AnotaceThis research investigated on Trans-activator of transcription (Tat) protein, a powerful viral gene activator that plays a pivotal role in the primary stage of the human immunodeficiency virus type 1 (HIV-1) replication. Dose-dependent interactions of HIV-1 Tat on NCD-EGFET-based RNA aptamer sensing surface were monitored and attained the detection down to 10 fM. The linear regression curve with 3σ estimation professed the sensitivity range to be 31.213 mV/log10 [Tat Concentration]M and the limit of detection of 6.18 fM. The selectivity analysis of NCD-EGFET was conducted with different proteins from HIV (Nef and p24) and Bovine Serum Albumin. Furthermore, to practice in the clinical application, HIV-1 Tat was spiked into the human blood serum and it displayed the genuine non-fouling interaction with the aptamer. The attained high-performance signal enhancement with nanocrystalline diamond-biosensing aids to circumvent the issues in the current diagnosis.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2021
    Elektronická adresahttps://ijneam.unimap.edu.my/images/PDF/IJNEAM%20APR%202020/Vol_13_No_2_2020_7_295-306.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.