High-pressure jet-induced hydrodynamic cavitation as a pre-treatment step for avoiding cyanobacterial contamination during water purification
- 1.
SYSNO ASEP 0533657 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název High-pressure jet-induced hydrodynamic cavitation as a pre-treatment step for avoiding cyanobacterial contamination during water purification Tvůrce(i) Zezulka, Štěpán (BU-J) ORCID
Maršálková, Eliška (BU-J) ORCID, SAI
Pochylý, F. (CZ)
Rudolf, P. (CZ)
Hudec, M. (CZ)
Maršálek, Blahoslav (BU-J) ORCID, SAIČíslo článku 109862 Zdroj.dok. Journal of Environmental Management. - : Elsevier - ISSN 0301-4797
Roč. 255, FEB 1 (2020), s. 1-7Poč.str. 7 s. Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova continuous treatment technology ; biotic contamination removal ; water treatment ; advanced oxidation processes Vědní obor RIV EH - Ekologie - společenstva Obor OECD Environmental sciences (social aspects to be 5.7) CEP GA16-18316S GA ČR - Grantová agentura ČR Způsob publikování Omezený přístup Institucionální podpora BU-J - RVO:67985939 UT WOS 000518708700017 EID SCOPUS 85075304838 DOI 10.1016/j.jenvman.2019.109862 Anotace Due to specific physical properties, hydrodynamic cavitation (HC) is assigned to the powerful technologies for treating the biotic contamination in water including cyanobacteria. Contaminated water stream (CWS) can be cavitated directly by passing through some HC device, or indirectly when high-pressure jet stream (HPJS) is directed against its flow. Relatively small HPJS stream can thus treat a big volume of CWS in a short time or even work in continuous mode. Cyanobacteria floating in the CWS are forced to flow through the mixing cavitation zone. Within 2 h after single HC treatment, cyanobacterial cell suspensions showed disintegration of larger colonies and enhanced biomass sedimentation. Additional pre-treatment of CWS with low amounts of hydrogen peroxide (H2O2, 33, 66 and 99 mu mol/L) enhanced the effect of HC and led to further inhibition of cyanobacterial photosynthesis (maximum quantum yield of photosystem II decreased by up to 60%). The number of cyanobacterial cells in the treated CWS decreased continuously over 48 and 72 h, though some cells remained alive and were able to recover photosynthetic activity. The technique proposed (direction of a HPJS against a CWS and pretreatment with low H2O2 concentrations) provides (i) effective removal of cells from the water column, and (ii) reduced contamination by organic compounds released from the cells (especially cyanotoxins) as the cell membranes are not destroyed and the cells remain alive. This process shows potential as an effective pretreatment step in water purification processes related to cyanobacterial contamination. Pracoviště Botanický ústav Kontakt Martina Bartošová, martina.bartosova@ibot.cas.cz, ibot@ibot.cas.cz, Tel.: 271 015 242 ; Marie Jakšová, marie.jaksova@ibot.cas.cz, Tel.: 384 721 156-8 Rok sběru 2021 Elektronická adresa https://doi.org/10.1016/j.jenvman.2019.109862
Počet záznamů: 1