Počet záznamů: 1  

Implant-forming polymeric 19F MRI-tracer with tunable dissolution

  1. 1.
    SYSNO ASEP0531585
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevImplant-forming polymeric 19F MRI-tracer with tunable dissolution
    Tvůrce(i) Kolouchová, Kristýna (UMCH-V) ORCID, RID
    Jirák, D. (CZ)
    Groborz, Ondřej (UMCH-V) ORCID, RID
    Sedlacek, O. (BE)
    Ziolkowska, N. (CZ)
    Vít, M. (CZ)
    Sticová, E. (CZ)
    Gálisová, A. (CZ)
    Švec, Pavel (UMCH-V) RID, ORCID
    Trousil, Jiří (UMCH-V) RID, ORCID
    Hajek, M. (CZ)
    Hrubý, Martin (UMCH-V) RID, ORCID
    Zdroj.dok.Journal of Controlled Release. - : Elsevier - ISSN 0168-3659
    Roč. 327, 10 November (2020), s. 50-60
    Poč.str.11 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovapolymer implant ; 19F magnetic resonance imaging ; double-stimuli responsivity
    Vědní obor RIVCD - Makromolekulární chemie
    Obor OECDPolymer science
    CEPLTC19032 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1507 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA18-07983S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUMCH-V - RVO:61389013
    UT WOS000585933700006
    EID SCOPUS85089267901
    DOI10.1016/j.jconrel.2020.07.026
    AnotaceMagnetic resonance imaging (MRI) using 19F-based tracers has emerged as a promising multi-purpose noninvasive diagnostic tool and its application requires the use of various 19F-based tracers for the intended diagnostic purpose. In this study, we report a series of double-stimuli-responsive polymers for use as injectable implants, which were designed to form implants under physiological conditions, and to subsequently dissolve with different dissolution rates (t1/2 ranges from 30 to more than 250 days). Our polymers contain a high concentration of fluorine atoms, providing remarkable signal detectability, and both a hydrophilic monomer and a pH-responsive monomer that alter the biodistribution properties of the implant. The implant location and dissolution were observed using 19F MRI, which allows the anatomic extent of the implant to be monitored. The dissolution kinetics and biocompatibility of these materials were thoroughly analyzed. No sign of toxicity in vitro or in vivo or pathology in vivo was observed, even in chronic administration. The clinical applicability of our polymers was further confirmed via imaging of a rat model by employing an instrument currently used in human medicine.
    PracovištěÚstav makromolekulární chemie
    KontaktEva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358
    Rok sběru2021
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S0168365920304107?via%3Dihub
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.