Počet záznamů: 1  

Methinium colorimetric sensors for the determination of cholesterol sulfate in an aqueous medium

  1. 1.
    SYSNO ASEP0507410
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevMethinium colorimetric sensors for the determination of cholesterol sulfate in an aqueous medium
    Tvůrce(i) Kejik, Z. (CZ)
    Havlík, M. (CZ)
    Bříza, T. (CZ)
    Kaplánek, R. (CZ)
    Dolenský, B. (CZ)
    Králová, Jarmila (UMG-J) RID
    Martásek, P. (CZ)
    Král, V. (CZ)
    Celkový počet autorů8
    Zdroj.dok.Sensors and Actuators B - Chemical. - : Elsevier
    Roč. 245, June (2017), s. 1032-1038
    Poč.str.7 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaCholesterol sulfate ; Sulfated lipids ; Steroids ; Chemical sensors ; Methinium salts ; Troger's bases
    Vědní obor RIVEB - Genetika a molekulární biologie
    Obor OECDBiochemistry and molecular biology
    CEPLQ1604 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUMG-J - RVO:68378050
    UT WOS000398760700121
    DOI10.1016/j.snb.2017.01.185
    AnotaceMethinium colorimetric sensors 1 and 2 were studied for the determination of cholesterol sulfate by UV-Vis spectroscopy in 0.001 M NaCl (H2O:MeOH, 7:3), pH = 7.34. Both of the tested sensors displayed high affinity, excellent selectivity and sensitivity for cholesterol sulfate against other steroids (estrone sulfate, pregnenolone sulfate, cholesterol, cholic acid and taurocholic acid). The determined values of conditional binding constants, linear ranges and detection limits demonstrated the high usability of these sensors for the determination of cholesterol sulfate. For example, the detection limits of tested sensors I and 2 for the detection of cholesterol sulfate were 0.16 mu M (0.07 mg/L, R-2 = 0.9966) and 1.3 mu M (0.59 mg/L, R-2 = 0.9872), respectively. Our detection limit strongly indicates the potential usability of these sensors for the determination of biologically important levels of cholesterol sulfate. (C) 2017 Elsevier B.V. All rights reserved.
    PracovištěÚstav molekulární genetiky
    KontaktNikol Škňouřilová, nikol.sknourilova@img.cas.cz, Tel.: 241 063 217
    Rok sběru2020
    Elektronická adresahttps://www.sciencedirect.com/science/article/abs/pii/S0925400517301909?via%3Dihub
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.