Surface tension measurements of viscous materials by pendant drop method: time needed to establish equilibrium shape

  1. 1.
    SYSNO ASEP0504710
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVO - Ostatní
    NázevSurface tension measurements of viscous materials by pendant drop method: time needed to establish equilibrium shape
    Tvůrce(i) Jůza, Josef (UMCH-V) RID, ORCID
    Číslo článku1800150
    Zdroj.dok.Macromolecular Symposia. Volume 384, Issue 1. - Weinheim : WILEY-VCH Verlag, 2019 / Lach R. ; Langer B. ; Michel P. - ISSN 1022-1360
    Rozsah stranroč. 384, č. 1 (2019), s. 1-12
    Poč.str.12 s.
    Forma vydáníTištěná - P
    AkcePolyMerTec18
    Datum konání13.06.2018 - 15.06.2018
    Místo konáníMerseburg
    ZeměDE - Německo
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovainterfacial tension ; measurement error ; pendant drop
    Vědní obor RIVCD - Makromolekulární chemie
    Obor OECDPolymer science
    CEPLO1507 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUMCH-V - RVO:61389013
    UT WOS000465042400006
    EID SCOPUS85064520966
    DOI10.1002/masy.201800150
    AnotaceThe pendant drop method of surface tension measurements published in 1938 has been frequently used since late 1960s. The time to reach equilibrium drop shape for viscous materials was mentioned in few papers only. The aim of this paper is to estimate time needed to reach a shape sufficiently close to equilibrium as a function of required precision and material viscosity. The procedure is based on Roe's error analysis of the pendant drop method and on a prerequisite of similarity in relaxation times of pendant drop and that of ellipsoid droplet published by Luciani and Utracki. An equation for time needed to reach equilibrium shape of pendant drop has been derived. Estimates have been verified through measurements of a test liquid, strong correction using empirical coefficients is needed to predict equilibration times correctly. The formula found is useful to assess whether the measurement can be accomplished before the material starts to degrade or otherwise change significantly. Since approximation using formula for ellipsoid relaxation is a weak point of the estimate, the challenge remaining for future is to describe the relaxation of pendant drop.