Počet záznamů: 1  

Saturation of a Ce:Y.sub.3./sub.Al.sub.5./sub.O.sub.12./sub. scintillator response to ultra-short pulses of extreme ultraviolet soft X-ray and X-ray laser radiation

  1. 1.
    SYSNO ASEP0502418
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSaturation of a Ce:Y3Al5O12 scintillator response to ultra-short pulses of extreme ultraviolet soft X-ray and X-ray laser radiation
    Tvůrce(i) Krzywinski, J. (US)
    Andrejczuk, A. (PL)
    Bionta, R.M. (US)
    Burian, Tomáš (FZU-D) RID, ORCID
    Chalupský, Jaromír (FZU-D) RID, ORCID
    Jurek, M. (PL)
    Kirm, M. (EE)
    Nagirnyi, V. (EE)
    Sobierajski, R. (PL)
    Tiedtke, K. (DE)
    Vielhauer, S. (EE)
    Juha, Libor (FZU-D) RID, ORCID, SAI
    Celkový počet autorů12
    Zdroj.dok.Optical Materials Express. - : Optical Society of America - ISSN 2159-3930
    Roč. 7, č. 3 (2017), s. 665-675
    Poč.str.11 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovafluorescent and luminescent materials ; luminescence ; free-electron lasers (FELs) ; UV ; EUV ; X-ray lasers ; laser beam characterization ; radiometr
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPLH14072 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LG15013 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA14-29772S GA ČR - Grantová agentura ČR
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000395672700002
    EID SCOPUS85014077941
    DOI10.1364/OME.7.000665
    AnotaceInvestigations of radioluminescence saturation in monocrystalline cerium doped yttrium aluminum garnet (Ce:YAG) exposed to intense extreme ultraviolet (XUV), soft X-ray and X-ray radiation delivered from three free-electron lasers are described in this article. The measurements were performed with wavelengths of 98, 25.6, 13.5 and 0.15 nm. We have found that saturation of the photon yield occurs at an excitation level of 2.0 x 1020 eV/cm3 resulting in an emission of 1.5 x 1018 visible photons per cubic centimeter. This number is much smaller than the concentration of Ce3+ in the scintillator that was equal to 2 x 1020 cm−3. Because the internal radiance efficiency η does not depend strongly on the irradiating photon energy, i.e., η ≈0.035 ± 0.015 in the range 10 to 100 000 eV, the results presented here could be used to predict saturation effects in scintillator slabs placed in imaging systems of bright XUV, X-ray and particle beams.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.