Počet záznamů: 1  

Effect of Cu-Zn coated steel fibers on high temperature resistance of reactive powder concrete

  1. 1.
    SYSNO ASEP0502032
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEffect of Cu-Zn coated steel fibers on high temperature resistance of reactive powder concrete
    Tvůrce(i) Scheinherrová, L. (CZ)
    Vejmelková, E. (CZ)
    Keppert, M. (CZ)
    Bezdička, Petr (UACH-T) SAI, RID, ORCID
    Doleželová, M. (CZ)
    Krejsova, J. (CZ)
    Grzeszczyk, S. (PL)
    Matuszek-Chmurowska, A. (PL)
    Černý, R. (CZ)
    Celkový počet autorů9
    Zdroj.dok.Cement and Concrete Research. - : Elsevier - ISSN 0008-8846
    Roč. 117, MAR (2019), s. 45-57
    Poč.str.13 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaThermal treatment ; Microstructure ; Corrosion ; Fiber reinforcement ; High-performance concrete
    Vědní obor RIVCA - Anorganická chemie
    Obor OECDInorganic and nuclear chemistry
    CEPGA17-11635S GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access s časovým embargem (01.03.2021)
    Institucionální podporaUACH-T - RVO:61388980
    UT WOS000458468700005
    EID SCOPUS85058820578
    DOI10.1016/j.cemconres.2018.12.008
    AnotaceEven though many studies have reported about the impacts of shape, length and distribution of steel fiber reinforcement on global concrete properties, there is a lack of information about the influence of coating type of steel fibers on high temperature resistance of concrete. This paper describes the effect of Cu-Zn coated steel fibers on selected properties of reactive powder concrete (RPC) after exposure to elevated temperatures. The initial corrosion of zinc in Cu-Zn surface layer is found to be already activated by the alkaline environment of the fresh concrete. The RPC samples reinforced with Cu-Zn coated steel fibers are heated to 600 degrees C and 1000 degrees C, and the influence of thermal load on microstructure, basic physical, mechanical, thermal and durability properties is analyzed. Based on the obtained results, it can be concluded that the maximal temperature to maintain effectiveness of the RPC reinforced with Cu-Zn steel fibers is 600 degrees C.
    PracovištěÚstav anorganické chemie
    KontaktJana Kroneislová, krone@iic.cas.cz, Tel.: 311 236 931
    Rok sběru2020
    Elektronická adresahttp://hdl.handle.net/11104/0293984
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.