Počet záznamů: 1  

Rapid fabrication of microextraction devices for direct determination of basic drugs in dried blood spots

  1. 1.
    SYSNO ASEP0499020
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevRapid fabrication of microextraction devices for direct determination of basic drugs in dried blood spots
    Tvůrce(i) Ryšavá, Lenka (UIACH-O) RID, ORCID, SAI
    Přikryl, Jan (UIACH-O) RID, ORCID
    Dvořák, Miloš (UIACH-O)
    Malá, Zdeňka (UIACH-O) RID
    Kubáň, Pavel (UIACH-O) RID, ORCID
    Celkový počet autorů5
    Zdroj.dok.CECE 2018. 15th International Interdisciplinary Meeting on Bioanalysis. - Brno : Ústav analytické chemie AV ČR, v. v. i., 2018 / Foret F. ; Křenková J. ; Drobníková I. ; Klepárník K. ; Přikryl J. - ISBN 978-80-904959-5-1
    Rozsah strans. 257-260
    Poč.str.4 s.
    Forma vydáníOnline - E
    AkceCECE 2018. International Interdisciplinary Meeting on Bioanalysis /15./
    Datum konání15.10.2018 - 17.10.2018
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovasupported liquid membrane (SLM) ; capillary electrophoresis ; microextraction devices
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    CEPGA18-13135S GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    AnotaceA 3D-printed cutter was designed for rapid fabrication of supported liquid membrane (SLM) extraction devices compatible with injection system of commercial capillary electrophoresis (CE) instrument. Low cost and single use microextraction devices were fabricated from polypropylene micropipette tips with high precision (dimension variances ≤ 3% RSD). Practical applicability of the microextraction devices was examined by in-line coupling of SLM extractions to CE for direct analysis of four model basic drugs in dried blood spot extracts. Excellent repeatability of the hyphenated technique was achieved (RSD ≤ 7.6%), transfer of analytes across the SLM ranged from 23 to 73% and limits of detection were as low as 0.07 μg/mL.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2019
    Elektronická adresahttp://www.ce-ce.org/user_uploads/program/CECE%202018%20Proceedings_WOS.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.