Počet záznamů: 1
Monitoring Candida parapsilosis and Staphylococcus epidermidis Biofilms by a Combination of Scanning Electron Microscopy and Raman Spectroscopy
- 1.
SYSNO ASEP 0497561 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Monitoring Candida parapsilosis and Staphylococcus epidermidis Biofilms by a Combination of Scanning Electron Microscopy and Raman Spectroscopy Tvůrce(i) Hrubanová, Kamila (UPT-D) RID, SAI, ORCID
Krzyžánek, Vladislav (UPT-D) RID, ORCID, SAI
Nebesářová, Jana (BC-A) RID, ORCID
Růžička, F. (CZ)
Pilát, Zdeněk (UPT-D) RID, SAI, ORCID
Samek, Ota (UPT-D) RID, ORCID, SAICelkový počet autorů 6 Číslo článku 4089 Zdroj.dok. Sensors. - : MDPI
Roč. 18, č. 12 (2018)Poč.str. 19 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova Raman spectroscopy ; biofilm ; sample preparation ; scanning electron microscopy ; cryo-SEM Vědní obor RIV JA - Elektronika a optoelektronika, elektrotechnika Obor OECD Microbiology CEP LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015062 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Institucionální podpora UPT-D - RVO:68081731 ; BC-A - RVO:60077344 UT WOS 000454817100008 EID SCOPUS 85057092615 DOI 10.3390/s18124089 Anotace The biofilm-forming microbial species Candida parapsilosis and Staphylococcus epidermidis have been recently linked to serious infections associated with implanted medical devices. We studied microbial biofilms by high resolution scanning electron microscopy (SEM), which allowed us to visualize the biofilm structure, including the distribution of cells inside the extracellular matrix and the areas of surface adhesion. We compared classical SEM (chemically fixed samples) with cryogenic SEM, which employs physical sample preparation based on plunging the sample into various liquid cryogens, as well as high-pressure freezing (HPF). For imaging the biofilm interior, we applied the freeze-fracture technique. In this study, we show that the different means of sample preparation have a fundamental influence on the observed biofilm structure. We complemented the SEM observations with Raman spectroscopic analysis, which allowed us to assess the time-dependent chemical composition changes of the biofilm in vivo. We identified the individual spectral peaks of the biomolecules present in the biofilm and we employed principal component analysis (PCA) to follow the temporal development of the chemical composition. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2019
Počet záznamů: 1