Počet záznamů: 1
High resolution Thomson scattering on the COMPASS tokamak - extending edge plasma view and increasing repetition rate
- 1.0489514 - ÚFP 2019 RIV GB eng J - Článek v odborném periodiku
Bílková, Petra - Böhm, Petr - Aftanas, Milan - Šos, Miroslav - Havránek, Aleš - Šesták, David - Weinzettl, Vladimír - Hron, Martin - Pánek, Radomír
High resolution Thomson scattering on the COMPASS tokamak - extending edge plasma view and increasing repetition rate.
Journal of Instrumentation. Roč. 13, č. 1 (2018), č. článku C01024. ISSN 1748-0221. E-ISSN 1748-0221.
[International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./. Prague, 24.09.2017-28.09.2017]
Grant CEP: GA ČR(CZ) GA14-35260S; GA MŠMT(CZ) 8D15001; GA MŠMT(CZ) LM2015045
GRANT EU: European Commission(XE) 633053 - EUROfusion
Institucionální podpora: RVO:61389021
Klíčová slova: Plasma diagnostics - interferometry * spectroscopy and imaging * Trigger concepts and systems (hardware and software)
Obor OECD: 2.11 Other engineering and technologies
Impakt faktor: 1.366, rok: 2018
http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01024/meta
The Thomson scattering (TS) diagnostic system on the COMPASS tokamak consists of separate collection optics for core and edge plasmas. Till now, the adverse orientation of the viewport available for the edge TS limited the investigated plasma scenarios to those, where H-mode plasma pedestal was possible to be observed. The vacuum vessel port has been recently modified and directed more to the plasma edge. To bridge the time for designing and manufacturing a new lens, the so far used edge TS collection lens was tilted and the fibre bundles rearranged to comply with the new geometry. However, the full potential of the new port is utilized only by the newly designed and manufactured lens. Comparison of performance of the collection lenses before and after the viewport modification is presented. Apart from the edge collection system upgrade, the laser system was extended by two lasers with parameters similar to the original two, thus increasing the repetition rate of the TS system to 120 Hz or allowing to obtain four profiles with tight timing in order to measure fast transient events in the plasma.
Trvalý link: http://hdl.handle.net/11104/0283917
Počet záznamů: 1