Počet záznamů: 1  

Study of the production yields of .sup.18./sup.F, .sup.11./sup.C, .sup.13./sup.N and .sup.15./sup.O positron emitters from plasma-laser proton sources at ELI-Beamlines for labeling of PET radiopharmaceuticals

  1. 1.
    SYSNO ASEP0488129
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevStudy of the production yields of 18F, 11C, 13N and 15O positron emitters from plasma-laser proton sources at ELI-Beamlines for labeling of PET radiopharmaceuticals
    Tvůrce(i) Amato, E. (IT)
    Italiano, A. (IT)
    Margarone, Daniele (FZU-D) RID, ORCID
    Pagano, B. (IT)
    Baldari, S. (IT)
    Korn, Georg (FZU-D) RID, ORCID
    Celkový počet autorů6
    Zdroj.dok.Nuclear Instruments & Methods in Physics Research Section A. - : Elsevier - ISSN 0168-9002
    Roč. 811, Mar (2016), s. 1-5
    Poč.str.5 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaplasma laser ; proton acceleration ; positron emission tomography ; microfluidics
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPED1.1.00/02.0061 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF15_008/0000162 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000368635700001
    EID SCOPUS84951783165
    DOI10.1016/j.nima.2015.12.011
    AnotaceThe development of novel compact PET radionuclide production systems is of great interest to promote the diffusion of PET diagnostics, especially in view of the continuous development of microfluidics labeling approaches. We studied the feasibility to produce clinically-relevant amounts of PET isotopes by means of laser-accelerated proton sources such that expected at the ELI-Beamlines facility. F-18, C-11, N-13 and O-15 production yields were calculated through the TALYS software, by taking into account the broad proton spectra expected. With the hypothesized proton fluencies, clinically-relevant amounts of radionuclides can be obtained, suitable to prepare single doses of F-18-, C-11- and N-13-labeled radio pharmaceuticals exploiting fast and efficient microfluidic labeling systems.