- Verification and validation of the R2Smesh approach for the calculati…
Počet záznamů: 1  

Verification and validation of the R2Smesh approach for the calculation of high resolution shutdown dose rate distributions

  1. 1.
    SYSNO ASEP0486431
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevVerification and validation of the R2Smesh approach for the calculation of high resolution shutdown dose rate distributions
    Tvůrce(i) Majerle, Mitja (UJF-V) RID, ORCID, SAI
    Leichtle, D. (DE)
    Fischer, U. (DE)
    Serikov, A. (DE)
    Celkový počet autorů4
    Zdroj.dok.Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
    Roč. 87, 5-6 (2012), s. 443-447
    Poč.str.5 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaMCNP ; FISPACT ; shutdown dose rate
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    Obor OECDNuclear physics
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000309781400013
    EID SCOPUS84865802111
    DOI https://doi.org/10.1016/j.fusengdes.2011.12.010
    AnotaceThe well validated Rigorous-2-Step (R2S) approach for the calculation of decay gamma shutdown dose rates has been extended utilizing mesh tally capabilities of the MCNP5 code. Contrary to other similar approaches, the new R2Smesh system pays special attention to achieving highly accurate and reliable results for neutron flux intensities and spectral shape in the initial MCNP5 neutron transport step. To this end, non-uniform fine and coarse meshes are adopted. Also several enhancements to the performance of activation calculations by FISPACT2007 and to sampling from repeated structures geometry have been implemented. The R2Smesh system has been verified by application to an ITER (International Thermonuclear Experimental Reactor) computational benchmark. An extensive validation exercise has been conducted on the FNG (Frascati Neutron Generator) shutdown dose rate benchmark. In this case several variants of the fine/coarse mesh spacing have been tested showing evidence for convergence toward R2S values obtained with the original cell-based approach. It thus has been shown that R2Smesh is validated for ITER applications and offers additional capabilities for high resolution shutdown dose rate calculations.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.