Correlative Fluorescence and Scanning Electron Microscopy of Labelled Core Fucosylated Glycans Using Cryosections Mounted on Carbon-Patterned Glass Slides

  1. 1.
    SYSNO ASEP0467725
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCorrelative Fluorescence and Scanning Electron Microscopy of Labelled Core Fucosylated Glycans Using Cryosections Mounted on Carbon-Patterned Glass Slides
    Tvůrce(i) Vancová, Marie (BC-A) RID, ORCID
    Nebesářová, Jana (BC-A) RID, ORCID
    Celkový počet autorů2
    Číslo článkue0145034
    Zdroj.dok.PLoS ONE. - : Public Library of Science - ISSN 1932-6203
    Roč. 10, č. 12 (2015)
    Poč.str.11 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovasalivary gland ; n-glycans ; tick ; glycosylation ; fucose ; sheep
    Vědní obor RIVEA - Morfologické obory a cytologie
    CEPTE01020118 GA TA ČR - Technologická agentura ČR
    Institucionální podporaBC-A - RVO:60077344
    UT WOS000367092300033
    EID SCOPUS84956660074
    DOI10.1371/journal.pone.0145034
    AnotaceThe aim of the study is co-localization of N-glycans with fucose attached to N-acetylglucosamine in alpha 1,3 linkage, that belong to immunogenic carbohydrate epitopes in humans, and N-glycans with alpha 1,6-core fucose typical for mammalian type of N-linked glycosylation. Both glycan epitopes were labelled in cryosections of salivary glands isolated from the tick Ixodes ricinus. Salivary glands secrete during feeding many bioactive molecules and influence both successful feeding and transmission of tick-borne pathogens. For accurate and reliable localization of labelled glycans in both fluorescence and scanning electron microscopes, we used carbon imprints of finder or indexed EM grids on glass slides. We discuss if the topographical images can provide information about labelled structures, the working setting of the field-emission scanning electron microscope and the influence of the detector selection (a below-the-lens Autrata improved YAG detector of back-scattered electrons; in-lens and conventional Everhart-Thornley detectors of secondary electrons) on the imaging of gold nanoparticles, quantum dots and osmium-stained membranes.