Počet záznamů: 1  

Time-resolved tuned diode laser absorption spectroscopy of pulsed plasma

  1. 1.
    SYSNO ASEP0439672
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevTime-resolved tuned diode laser absorption spectroscopy of pulsed plasma
    Tvůrce(i) Adámek, Petr (FZU-D) RID, ORCID
    Do, H.T. (DE)
    Čada, Martin (FZU-D) RID, ORCID, SAI
    Hubička, Zdeněk (FZU-D) RID, ORCID, SAI
    Hippler, R. (DE)
    Zdroj.dok.Journal of Physics: Conference Series, 511. - Bristol : IOP Publishing, 2014 - ISSN 1742-6596
    Rozsah stran"012088-1"-"012088-6"
    Poč.str.6 s.
    Forma vydáníTištěná - P
    AkceInternational Congress on Plasma Physics (ICPP) / 13th Latin American Workshop on Plasma Physics (LAWPP)/15./
    Datum konání08.08.2010-13.08.2010
    Místo konáníSantiago, CHILE
    ZeměCL - Chile
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovamagnetron discharge ; aluminum
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPKAN301370701 GA AV ČR - Akademie věd
    GP202/09/P159 GA ČR - Grantová agentura ČR
    KJB100100805 GA AV ČR - Akademie věd
    1M06002 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000337223400088
    EID SCOPUS84901639737
    DOI10.1088/1742-6596/511/1/012088
    AnotaceA novel method for time-resolved tuned diode laser absorption spectroscopy has been developed. In this paper, we describe in detail developed electronic module that controls time-resolution of laser absorption spectroscopy system. The TTL signal triggering plasma pulse is used for generation of two signals: the first one triggers the fine tuning of laser wavelength and second one controls time-defined signal sampling from absorption detector. The described method and electronic system enable us to investigate temporal evolution of sputtered particles in technological low-temperature plasma systems. The pulsed DC planar magnetron sputtering system has been used to verify this method. The 2” in diameter titanium target was sputtered in pure argon atmosphere. The working pressure was held at 2 Pa. All the experiments were carried out for pulse ON time fixed at 100 μs.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.