Počet záznamů: 1
Silica-based monolithic capillary columns modified to zwitterionic stationary phase for hydrophilic interaction liquid chromatography
- 1.
SYSNO ASEP 0386068 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Silica-based monolithic capillary columns modified to zwitterionic stationary phase for hydrophilic interaction liquid chromatography Tvůrce(i) Moravcová, Dana (UIACH-O) RID, ORCID
Planeta, Josef (UIACH-O) RID, ORCID
Kahle, Vladislav (UIACH-O) RID
Horká, Marie (UIACH-O) RID, ORCID
Roth, Michal (UIACH-O) RID, ORCIDCelkový počet autorů 5 Zdroj.dok. CECE 2012. 9th International Interdisciplinary Meeting on Bioanalysis. - Brno : Ústav analytické chemie AV ČR, v. v. i, 2012 / Foret František ; Křenková Jana ; Guttman Andras ; Klepárník Karel ; Boček Petr - ISBN 978-80-904959-1-3 Rozsah stran s. 300-303 Poč.str. 4 s. Forma vydání Tištěná - P Akce CECE 2012. International Interdisciplinary Meeting on Bioanalysis /9./ Datum konání 01.11.2012-02.11.2012 Místo konání Brno Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. CZ - Česká republika Klíč. slova zwitterionic stationary phase ; HILIC ; phenolic acids Vědní obor RIV CB - Analytická chemie, separace CEP VG20112015021 GA MV - Ministerstvo vnitra GAP206/11/0138 GA ČR - Grantová agentura ČR GAP106/12/0522 GA ČR - Grantová agentura ČR Institucionální podpora UIACH-O - RVO:68081715 UT WOS 000329635000084 Anotace Zwitterionic monolithic capillary columns intended for isocratic gradient hydrophilic interaction chromatography (HILIC) separations are introduced. Silica-based capillary columns (150 mm x 0.1 mm) were prepared by acidic hydrolysis of tetramethoxysilane in the presence of polyethylene glycol and urea. The modification by a 3-(trimethoxysilyl)propyl methacrylate and then by a zwitterionic [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide to HILIC stationary phase bearing sulfoalkylbetaine groups on its surface followed. Prepared columns were characterized in HILIC separation mode employing mobile phase containing 10% (v/v) of 5 mM ammonium acetate pH = 4.5 in acetonitrile. Comparison with the commercially available ZIC-HILIC® column (Merck SeQuant®) under the same separation conditions using a mixture of aromatic carboxylic acids as a sample was done on the basis of separation efficiency of tested columns as well as retention factors and peak asymmetry of individual solutes. Pracoviště Ústav analytické chemie Kontakt Iveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234 Rok sběru 2013 Elektronická adresa http://hdl.handle.net/11104/0215358
Počet záznamů: 1