Počet záznamů: 1  

Silica-based monolithic capillary columns modified to zwitterionic stationary phase for hydrophilic interaction liquid chromatography

  1. 1.
    SYSNO ASEP0386068
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevSilica-based monolithic capillary columns modified to zwitterionic stationary phase for hydrophilic interaction liquid chromatography
    Tvůrce(i) Moravcová, Dana (UIACH-O) RID, ORCID
    Planeta, Josef (UIACH-O) RID, ORCID
    Kahle, Vladislav (UIACH-O) RID
    Horká, Marie (UIACH-O) RID, ORCID
    Roth, Michal (UIACH-O) RID, ORCID
    Celkový počet autorů5
    Zdroj.dok.CECE 2012. 9th International Interdisciplinary Meeting on Bioanalysis. - Brno : Ústav analytické chemie AV ČR, v. v. i, 2012 / Foret František ; Křenková Jana ; Guttman Andras ; Klepárník Karel ; Boček Petr - ISBN 978-80-904959-1-3
    Rozsah strans. 300-303
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceCECE 2012. International Interdisciplinary Meeting on Bioanalysis /9./
    Datum konání01.11.2012-02.11.2012
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovazwitterionic stationary phase ; HILIC ; phenolic acids
    Vědní obor RIVCB - Analytická chemie, separace
    CEPVG20112015021 GA MV - Ministerstvo vnitra
    GAP206/11/0138 GA ČR - Grantová agentura ČR
    GAP106/12/0522 GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    UT WOS000329635000084
    AnotaceZwitterionic monolithic capillary columns intended for isocratic gradient hydrophilic interaction chromatography (HILIC) separations are introduced. Silica-based capillary columns (150 mm x 0.1 mm) were prepared by acidic hydrolysis of tetramethoxysilane in the presence of polyethylene glycol and urea. The modification by a 3-(trimethoxysilyl)propyl methacrylate and then by a zwitterionic [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide to HILIC stationary phase bearing sulfoalkylbetaine groups on its surface followed. Prepared columns were characterized in HILIC separation mode employing mobile phase containing 10% (v/v) of 5 mM ammonium acetate pH = 4.5 in acetonitrile. Comparison with the commercially available ZIC-HILIC® column (Merck SeQuant®) under the same separation conditions using a mixture of aromatic carboxylic acids as a sample was done on the basis of separation efficiency of tested columns as well as retention factors and peak asymmetry of individual solutes.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2013
    Elektronická adresahttp://hdl.handle.net/11104/0215358
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.