Počet záznamů: 1  

Measurement of Carbon Diffusion Coeficient - Calibration of Sputter Depth

  1. 1.
    SYSNO ASEP0385390
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevMeasurement of Carbon Diffusion Coeficient - Calibration of Sputter Depth
    Tvůrce(i) Král, Lubomír (UFM-A) RID, ORCID
    Čermák, Jiří (UFM-A) RID, ORCID
    Celkový počet autorů2
    Zdroj.dok.METAL 2012 Conference Proceedings. - Ostrava : TANGER Ltd. Ostrava, 2012 - ISBN 978-80-87294-31-4
    Rozsah strans. 121-126
    Poč.str.2 s.
    Forma vydáníNosič - C
    AkceMetal 2012
    Datum konání23.05.2012-25.05.2012
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovacarbon diffusion ; ferrite ; SIMS ; carbides
    Vědní obor RIVBJ - Termodynamika
    CEPGAP108/11/0148 GA ČR - Grantová agentura ČR
    Institucionální podporaUFM-A - RVO:68081723
    CEZAV0Z20410507 - UFM-A (2005-2011)
    UT WOS000318506500099
    AnotaceDepth profiling mode of MiniSIMS device was applied to diffusion measurement. Calibration of crater depth was done using shearing interference microscope Zeiss Epival Interphako (ZEI) and confocal mikroskope Olympus LEXT OLS3100 with atomic force microscopy (AFM) modul. The ZEI uses one of the classical interferometric measuring methods. Generally this method leads to results with considerable experimental error. AFM is a very high-resolution type of scanning probe microscopy, with typical resolution of the order of fractions of nanometers, which is more than 1000 times better than the optical diffraction limit. However, the results taken by ZEI were in agreement with much more precise results of surface profiling achieved by AFM. It was found, at given experimental conditions (Fe-rich matrix, Ga + primary ions, 5 kV/3nA, DWT=1), that the sputter rate is some 0.3 nm per a single sputter scan of the crater area (50x50 µm). This depth calibration with SIMS technique can be applied to the study of carbon diffusion in BCC iron as an example. Special technique was developed, which avoids radio-tracer measurements with C-14. Obtained results are lower than the extrapolated values, which may be due to limited solubility of carbon in iron.
    PracovištěÚstav fyziky materiálu
    KontaktYvonna Šrámková, sramkova@ipm.cz, Tel.: 532 290 485
    Rok sběru2013
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.