Air Flow Rates and Penetration Factors Estimated Through Multi-Compartment Indoor Aerosol Model Simulations
- 1.0347738 - ÚCHP 2011 FI eng C - Konferenční příspěvek (zahraniční konf.)
Mølgaard, B. - Tareq, H. - Ondráček, Jakub - Smolík, Jiří
Air Flow Rates and Penetration Factors Estimated Through Multi-Compartment Indoor Aerosol Model Simulations.
Registration Handbook. Helsinki: -, 2010, 11F4. ISBN N.
[International Aerosol Conference IAC 2010. Helsinki (FI), 29.08.2010-03.09.2010]
Grant CEP: GA ČR GA101/07/1361
Výzkumný záměr: CEZ:AV0Z40720504
Klíčová slova: indoor aerosols * modelling * flow rates
Kód oboru RIV: CF - Fyzikální chemie a teoretická chemie
www.iac2010.fi
In this study we made extensive model simulations with the Multi-Compartment Size resolved Indoor Aerosol Model (MC-SIAM) to investigate these influencing factors according to the procedure described by Hussein et al. (2005). The model simulations were compared to the real conditions according to measurements of particle number size distributions inside a multi-zone apartment located in Prague, Czech Republic.