Počet záznamů: 1
Diagnostic Studies of Severe Convective Precipitation Events - Effects of Propagating Gust Fronts
- 1.
SYSNO ASEP 0104058 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Diagnostic Studies of Severe Convective Precipitation Events - Effects of Propagating Gust Fronts Překlad názvu Diagnostické studie srážkově významných konvektivních událostí - vliv postupujících gust front Tvůrce(i) Kašpar, Marek (UFA-U) RID, ORCID Zdroj.dok. Presentations (in PPS or PDF) held at the Seminar 2004 of the LM User Group. - Offenbach : Deutscher Wetterdienst (DWD), 2004 Rozsah stran s. 1-28 Poč.str. 28 s. Forma vydání WEB - WEB Akce Seminar 2004 of the LM User Group Datum konání 08.03.2004-10.03.2004 Místo konání Langen Země DE - Německo Typ akce WRD Jazyk dok. eng - angličtina Země vyd. DE - Německo Klíč. slova Gust front ; numerical modelling ; objective analysis Vědní obor RIV DG - Vědy o atmosféře, meteorologie CEP KJB3042404 GA AV ČR - Akademie věd GA205/04/0114 GA ČR - Grantová agentura ČR CEZ AV0Z3042911 - UFA-U, BC-A Anotace The results of previous studies showed that the LM-COSMO together with objective methods for gust front analysis are capable to simulate thermodynamic processes associated with convective outflows. Thus, they may represent the potential for improving the nowcasting and short-range forecasting of hazardous weather phenomena. The presented analyses follow-up to the case studies of the events from July 1998 and 2000, when different types of convective systems caused heavy precipitation in the territory of the Czech Republic. The analyses are aimed at the simulation and more detailed study of the events to clarify the effect of propagating gust fronts in the development and organization of convection, as they propagated into shear-favourable environment. For occasion, the case-appropriate LM run version 3.3 with horizontal resolution 2.8km is employed. The position and movement of gust fronts are determined with the aid of objective techniques based on an objective frontal analysis model. If it is possible, the appropriate propagating regimes are subjectively assigned to examined gust fronts according to the properties of ambient flow. The Radar Simulation Model RSM is applied to verify the individual LM runs. The RSM outputs are compared with corresponding data from Czech radars Pracoviště Ústav fyziky atmosféry Kontakt Kateřina Adamovičová, adamovicova@ufa.cas.cz, Tel.: 272 016 012 ; Kateřina Potužníková, kaca@ufa.cas.cz, Tel.: 272 016 019 Rok sběru 2005
Počet záznamů: 1