Počet záznamů: 1  

Effect of surface carbonitriding by plasma immersion ion implantation on the fatigue behaviour of 316L austenitic stainless stee

  1. 1.
    SYSNO ASEP0026256
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevEffect of surface carbonitriding by plasma immersion ion implantation on the fatigue behaviour of 316L austenitic stainless stee
    Překlad názvuVliv povrchové karbonitridace plazmovou imerzní iontovou implantací na únavové chování austenitické nerezavějící oceli 316L
    Tvůrce(i) Obrtlík, Karel (UFM-A) RID, ORCID
    Jirásková, Yvonna (UFM-A) RID, ORCID
    Man, Jiří (UFM-A) RID, ORCID
    Polák, Jaroslav (UFM-A) RID, ORCID
    Zdroj.dok.Computer Methods and Experimental Measurements for Surface Effects and Contact Mechanics /7./. - Southampton : WIT Press, 2005 / De Hosson J.T.M. ; Brebia C.A. ; Nishida S.I. - ISBN 1-84564-022-5
    Rozsah strans. 13-22
    Poč.str.10 s.
    AkceContact Surface 2005 /7./
    Datum konání05.09.2005-07.09.2005
    Místo konáníBologna
    ZeměIT - Itálie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaaustenitic stainless steel ; fatigue life curves ; plasma immersion ion implantation
    Vědní obor RIVJL - Únava materiálu a lomová mechanika
    CEPGA106/03/1265 GA ČR - Grantová agentura ČR
    1QS200410502 GA AV ČR - Akademie věd
    ME 373 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z20410507 - UFM-A (2005-2011)
    AnotaceCylindrical specimens of 316L austenitic stainless steel in as-received condition and with surface carbonitriding by plasma immersion ion implantation were cyclically strained under plastic strain control. Micro-hardness depth profile of hardened surface layer was measured. Mössbauer spectroscopy and X-ray diffraction were used to study the phase composition of the treated layer. Stress-strain response and fatigue life data of both materials were obtained. Surface relief and fracture surface were examined to study fatigue damage mechanisms. Two domains separated by the transitional plastic strain amplitude could be distinguished in fatigue behaviour of the treated steel. In the low amplitude domain, the main crack originates in subsurface region resulting in the prolonged lifetime. The main crack initiates at the surface in the high amplitude domain and the fatigue life of the treated steel is reduced compared to the untreated one.