Počet záznamů: 1  

Ion energy distributions at substrate in bipolar HiPIMS: effect of positive pulse delay, length and amplitude

  1. 1.
    0534021 - FZÚ 2021 RIV GB eng J - Článek v odborném periodiku
    Kozák, T. - Pajdarova, A.D. - Čada, Martin - Hubička, Zdeněk - Mareš, P. - Čapek, J.
    Ion energy distributions at substrate in bipolar HiPIMS: effect of positive pulse delay, length and amplitude.
    Plasma Sources Science & Technology. Roč. 29, č. 6 (2020), s. 1-10, č. článku 065003. ISSN 0963-0252. E-ISSN 1361-6595
    Grant CEP: GA MPO FV30177
    Institucionální podpora: RVO:68378271
    Klíčová slova: HiPIMS * bipolar HiPIMS * positive pulse * plasma diagnostics * mass spectroscopy
    Obor OECD: Fluids and plasma physics (including surface physics)
    Impakt faktor: 3.584, rok: 2020
    Způsob publikování: Omezený přístup
    https://doi.org/10.1088/1361-6595/ab8fbb

    A bipolar HiPIMS discharge with a rectangular positive voltage pulse (with controllable amplitude, delay after the main negative pulse and positive pulse length) was systematically investigated by mass spectroscopy. The time-averaged spectra of ions measured at the substrate position exhibit a prominent high-energy peak. It is shown that the position of the peak can be varied by the positive pulse amplitude, its magnitude scales with the pulse length and its width can be slightly influenced by the length of the delay interval. Measurements of the plasma potential at the mass spectrometer position and time-resolved mass spectroscopy clearly show that the high-energy peak is formed by ions accelerated by the elevated plasma potential during the positive pulse. In addition, fine details of the ion energy distribution functions related to the plasma potential transients at the start of the positive pulse are identified.
    Trvalý link: http://hdl.handle.net/11104/0312242

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.