Počet záznamů: 1  

Noninvasive Optical Measurement of Elastic Tube Deformations

  1. 1.
    0092668 - ÚT 2008 RIV CZ eng C - Konferenční příspěvek (zahraniční konf.)
    Macková, H. - Chlup, Hynek - Žitný, R.
    Noninvasive Optical Measurement of Elastic Tube Deformations.
    [Neinvazivní potické měření deformací elastických trubic.]
    International Conference on Computational Biomechanics and Biology. Plzeň: University of West Bohemia, 2007, s. 1-4. ISBN 978-80-7043-607-3.
    [ICCBB 2007. Plzeň (CZ), 10.09.2007-13.09.2007]
    Výzkumný záměr: CEZ:AV0Z20760514
    Klíčová slova: elastic tube * high-speed camera recordings * optical measurement
    Kód oboru RIV: BK - Mechanika tekutin

    Noninvasive optical measurement and evaluation of the pulse wave velocity of a self-oscillating elastic tube was done. A latex tube was loaded by self-excited internal pulsatile flow as a simple model of human big arteries. The method is based on evaluation of high speed camera recordings and edges detection algorithm. Displacements of the tube edge were evaluated by a given scale factor from a standard gauge inserted to the recorded scene. Our goal is to recognize the pulse wave and measure its velocity along the tube.

    Bylo provedeno oeinvazivní optické měření a posuzení rychlosti pulzní vlny oscilující elastické trubice. Latexová trubka byla zatížena samooscilujícím vnítřním tokem, jako jednoduchý model lidských velkých tepen. Metoda je založena na zpracování snímků z vysokorychlostní kamery s algoritmem na detekci hran trubice. Deformace hrany trubice byla zjišťována pomocí daného měřítka, vloženého do nahrávané scény. Naším cílem je rozeznat pulzní vlnu a změřit její rychlost podél trubice.
    Trvalý link: http://hdl.handle.net/11104/0152926

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.