- Very high frequency induced fatigue damage
Počet záznamů: 1  

Very high frequency induced fatigue damage

  1. 1.
    0588417 - ÚFM 2025 RIV NL eng J - Článek v odborném periodiku
    Fintová, Stanislava - Kuběna, Ivo - Chlupová, Alice - Šulák, Ivo - Chlup, Zdeněk - Trško, L. - Polák, Jaroslav
    Very high frequency induced fatigue damage.
    Theoretical and Applied Fracture Mechanics. Roč. 133, OCT (2024), č. článku 104590. ISSN 0167-8442. E-ISSN 1872-7638
    Grant CEP: GA MŠMT(CZ) EH22_008/0004634
    Institucionální podpora: RVO:68081723
    Klíčová slova: high-cycle fatigue * loading frequency * plasticity * Very high cycle fatigue * Very high-frequency loading * Steel * Fatigue damage * FIB tomography * Cavities
    Obor OECD: Materials engineering
    Impakt faktor: 5, rok: 2023 ; AIS: 0.827, rok: 2023
    Způsob publikování: Open access
    Web výsledku:
    https://www.sciencedirect.com/science/article/pii/S0167844224003409?via%3DihubDOI: https://doi.org/10.1016/j.tafmec.2024.104590

    Fatigue lifetime and fatigue endurance limit are enhanced by the increased strain rate for many materials. Consequently, ultrasonic fatigue testing yields an S-N curve well above the conventionally obtained ones for the strain rate sensitive materials. Thus, understanding of the fatigue damage mechanisms operating under very high frequencies and their relation to the conventional testing results is crucial for lifetime prediction in the very high cycle fatigue region. he increase in test frequency from 20 Hz to 20 kHz enhances the fatigue life and the fatigue endurance limit of the ferritic-pearlitic structure steel. On the other hand, the character of the created surface relief was similar for all the test conditions in terms of test frequency and stress amplitude applied. The increased testing frequency reduced the number of slip markings. Nevertheless, it seems that test frequency only slightly impacted the height/depth of the extrusions/intrusions. Focused ion beam tomography and 3D reconstruction of the volume below the slip markings demonstrated the cavity distribution within the material volume and along the slip plane. No slip markings were observed in the pearlite areas. Fatigue crack initiation occurred predominantly in the slip markings, however, subsurface cavity-assisted crack initiation was occasionally observed, too. Coalescence of cavities along the slip plane facilitated the fatigue crack initiation and early growth. No difference in damage mechanism was detected regardless of the test frequency or stress amplitude.
    Trvalý link: https://hdl.handle.net/11104/0355325
    Vědecká data: Zenodo
     
    Název souboruStaženoVelikostKomentářVerzePřístup
    1946_167266256664f0b6e3ed379684760b48.pdf54.4 MBVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.