Photoacoustic spectroscopy using a quantum cascade laser for analysis of ammonia in water solutions

  1. 1.
    0587074 - FZÚ 2025 RIV US eng J - Článek v odborném periodiku
    Apostolakis, Apostolos - Aoust, G. - Maisons, G. - Laurent, L. - Pereira, Mauro Fernandes
    Photoacoustic spectroscopy using a quantum cascade laser for analysis of ammonia in water solutions.
    ACS Omega. Roč. 9, č. 17 (2024), s. 19127-19135. ISSN 2470-1343. E-ISSN 2470-1343
    GRANT EU: European Commission(XE) 832876 - aqua3S; European Commission(XE) 101021857 - ODYSSEUS
    Institucionální podpora: RVO:68378271
    Klíčová slova: absorption * ammonia * computer simulations * molecules * sensors * photoacoustic detection * NEGF * QCL
    Obor OECD: Optics (including laser optics and quantum optics)
    Impakt faktor: 4.1, rok: 2022
    Způsob publikování: Open access

    Ammonia (NH3) toxicity, stemming from nitrification, can adversely affect aquatic life and influence the taste and odor of drinking water. This underscores the necessity for highly responsive and accurate sensors to continuously monitor NH3 levels in water, especially in complex environments where reliable sensors have been lacking until this point. Herein, we detail the development of a sensor comprising a compact and selective analyzer with low gas consumption and a timely response, based on photoacoustic spectroscopy. This, combined with an automated liquid sampling system, enables the precise detection of ammonia traces in water. The sensor system incorporates a state-of-the art quantum cascade laser as the excitation source emitting at 9 μm in resonance with the absorption line of NH$_3$ located at 1103.46 cm$^{-1}$. Our instrument demonstrated detection sensitivity at low ppm level for ammonia molecule with response times less than 60 seconds. For the sampling system, an ammonia stripping solution was designed resulting in a prompt full measurement cycle (6.35 min). A further evaluation of the sensor within a pilot study showed good reliability and agreement with the reference method for real water samples, confirming the potential of our NH3 analyzer for water-quality monitoring applications.
    Trvalý link: https://hdl.handle.net/11104/0354376

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0587074.pdf03.6 MBCC LicenceVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.