Počet záznamů: 1  

Determining the Nanoflare Heating Frequency of an X-Ray Bright Point Observed by MaGIXS

  1. 1.
    0586241 - ASÚ 2025 RIV GB eng J - Článek v odborném periodiku
    Mondal, B. - Athiray, P. S. - Winebarger, A. - Dudík, Jaroslav … celkem 21 autorů
    Determining the Nanoflare Heating Frequency of an X-Ray Bright Point Observed by MaGIXS.
    Astrophysical Journal. Roč. 967, č. 1 (2024), č. článku 23. ISSN 0004-637X. E-ISSN 1538-4357
    Institucionální podpora: RVO:67985815
    Klíčová slova: solar coronal heating * solar coronal loops * solar x-ray emission
    Obor OECD: Astronomy (including astrophysics,space science)
    Impakt faktor: 4.9, rok: 2022
    Způsob publikování: Open access

    Nanoflares are thought to be one of the prime candidates that can heat the solar corona to its multimillion kelvin temperature. Individual nanoflares are difficult to detect with the present generation of instruments, but their presence can be inferred by comparing simulated nanoflare-heated plasma emissions with the observed emission. Using HYDRAD coronal loop simulations, we model the emission from an X-ray bright point (XBP) observed by the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS), along with the nearest available observations from the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory (SDO) and the X-Ray Telescope (XRT) on board the Hinode observatory. The length and magnetic field strength of the coronal loops are derived from the linear force-free extrapolation of the observed photospheric magnetogram by the Helioseismic and Magnetic Imager on board SDO. Each loop is assumed to be heated by random nanoflares, whose magnitude and frequency are determined by the loop length and magnetic field strength. The simulation results are then compared and matched against the measured intensity from AIA, XRT, and MaGIXS. Our model results indicate the observed emission from the XBP under study could be well matched by a distribution of nanoflares with average delay times 1500-3000 s. Further, we demonstrate the high sensitivity of MaGIXS and XRT for diagnosing the heating frequency using this method, while AIA passbands are found to be the least sensitive.
    Trvalý link: https://hdl.handle.net/11104/0354011

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    586241.pdf02.6 MBVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.