Počet záznamů: 1  

Improvements in digital meteor spectra reduction

  1. 1.
    0584797 - ASÚ 2025 RIV DE eng J - Článek v odborném periodiku
    Šegon, Marko - Vojáček, Vlastimil - Borovička, Jiří
    Improvements in digital meteor spectra reduction.
    Experimental Astronomy. Roč. 57, č. 2 (2024), č. článku 9. ISSN 0922-6435. E-ISSN 1572-9508
    Grant CEP: GA ČR(CZ) GX19-26232X
    Institucionální podpora: RVO:67985815
    Klíčová slova: data analysis * observational techniques * imaging spectroscopy
    Obor OECD: Astronomy (including astrophysics,space science)
    Impakt faktor: 3, rok: 2022
    Způsob publikování: Open access

    This study addresses the complexity and importance of developing a method of calibrating digital observations of meteor spectra with all-sky cameras. It aims to present novel approaches to spectral sensitivity, atmospheric extinction and flat-field corrections. Images of a known line emission spectrum were captured at various positions within the field of view using a camera with a fish-eye lens and plastic holographic grating. The flat-field correction was separated into a wavelength-independent and wavelength-dependent component, both dependent on the position of the spectral line in the field of view (FoV). Total profile intensities of spectra obtained from the images were compared throughout the spectral range at different positions in the FoV. The flat-field was constructed by fitting those dependencies with high-degree polynomial functions. Using a simplified atmospheric model, a novel approach was constructed to determine the atmospheric extinction curve throughout the spectral range, allowing it to be separately considered from the spectral sensitivity which was previously not the case. A comparison of the newly developed and previously used methodology was tested on several meteor spectra of the same meteor captured from different stations of the European Fireball Network. It revealed a significantly improved correspondence of the analysed spectra in the part of the spectral range unaffected by the limitations imposed by the newly developed methodology. Failing to follow the correct calibration methodology precisely may introduce varying degrees of uncertainty in computations of elemental abundances and other physical properties, depending on the equipment's specific effect magnitude.
    Trvalý link: https://hdl.handle.net/11104/0354153

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    584797.pdf14.5 MBVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.