Počet záznamů: 1  

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

  1. 1.
    0582700 - ÚFP 2024 RIV GB eng J - Článek v odborném periodiku
    Makarov, S. - Makita, M. - Nakatsutsumi, M. - Pikuz, T.A. - Ozaki, N. - Preston, T.R. - Appel, K. - Konopková, Z. - Cerantola, V. - Brambrink, E. - Schwinkendorf, J.P. - Mohacsi, I. - Burian, Tomáš - Chalupský, J. - Hájková, V. - Juha, L. - Vozda, V. - Nagler, B. - Zastrau, U. - Pikuz, S. - Yabashi, M.
    Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument.
    Journal of Synchrotron Radiation. Roč. 30, January (2023), s. 208-216. ISSN 0909-0495. E-ISSN 1600-5775
    Grant CEP: GA ČR(CZ) GA20-08452S
    Institucionální podpora: RVO:61389021
    Klíčová slova: compound refractive lenses * focusing system * lithium fluoride (LiF) detector * X-ray beam characterization * X-ray focusing * X-ray free-electron lasers
    Obor OECD: Optics (including laser optics and quantum optics)
    Impakt faktor: 2.5, rok: 2022
    Způsob publikování: Open access
    https://scripts.iucr.org/cgi-bin/paper?S1600577522006245

    The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra-intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.
    Trvalý link: https://hdl.handle.net/11104/0350782

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.